DESCRIPTION
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P314A | 828 | Open in the inverter water pump assembly speed signal line or inverter water pump assembly power source circuit. |
|
WIRING DIAGRAM
Refer to the wiring diagram for DTC P0C73-776 Click here.
INSPECTION PROCEDURE
Note
If DTC P0A78-284, 286, P0A79-692, 696, P0A7A-322, 324, P0A94-553 or 557 is output, replace the inverter with converter assembly after this inspection.
PROCEDURE
PERFORM ACTIVE TEST USING INTELLIGENT TESTER (ACTIVATE THE WATER PUMP)
Note
Be sure to perform the inspection with the auxiliary battery voltage at 11 V or more.
Tech Tips
When the auxiliary battery voltage is low, the inverter water pump assembly may not operate.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Active Test / Activate the Water Pump.
Perform the Activate the Water Pump Active Test.
Touch the inverter water pump assembly and check that it is operating (vibrating).
| OK |
|---|
| The inverter water pump assembly is operating (vibrating). |
Turn the power switch off.
| NG |
|
CHECK FUSE (INV W/P) Click here |
| OK |
|
CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)
Check the connections of the power management control ECU connectors.
| *1 | for LHD | *2 | for RHD |
| OK |
|---|
| The connectors are connected securely and there are no contact problems. |
| NG |
|
CONNECT SECURELY |
| OK |
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WATER PUMP ASSEMBLY CONNECTOR)
Check the connection of the inverter water pump assembly connector.
| OK |
|---|
| The connector is connected securely and there are no contact problems. |
| NG |
|
CONNECT SECURELY |
| OK |
|
CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - WATER PUMP WITH MOTOR)
Disconnect connector A80 from the power management control ECU.
Disconnect connector A73 from the inverter water pump assembly.
Measure the resistance according to the value(s) in the table below.
| *1 | Rear view of wire harness connector (to Power Management Control ECU) |
*2 | Front view of wire harness connector (to Inverter Water Pump Assembly) |
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Connect the power management control ECU connector.
Connect the inverter water pump assembly connector.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK POWER MANAGEMENT CONTROL ECU
Disconnect connector A73 from the inverter water pump assembly.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
Turn the power switch off.
Connect the inverter water pump assembly connector.
| B |
|
REPLACE POWER MANAGEMENT CONTROL ECU (for LHD) Click here |
| C |
|
REPLACE POWER MANAGEMENT CONTROL ECU (for RHD) Click here |
| A |
|
REPLACE INVERTER WATER PUMP ASSEMBLY Click here
CHECK FUSE (INV W/P)
| *1 | Engine Room Relay Block No. 2 |
| *2 | INV W/P Fuse |
Remove the INV W/P fuse from the engine room relay block No. 2.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Install the INV W/P fuse.
| NG |
|
| OK |
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WATER PUMP ASSEMBLY CONNECTOR)
Check the connection of the inverter water pump assembly connector.
| OK |
|---|
| The connector is connected securely and there are no contact problems. |
| NG |
|
CONNECT SECURELY |
| OK |
|
CHECK HARNESS AND CONNECTOR (INVERTER WATER PUMP ASSEMBLY CIRCUIT)
Remove the INV W/P fuse from the engine room relay block No. 2.
Remove the IGCT MAIN relay from the engine room relay block No. 2.
Disconnect connector A80 from the power management control ECU.
Disconnect connector A73 from the inverter water pump assembly.
Measure the resistance according to the value(s) in the table below.
| *1 | Front view of wire harness connector (to Power Management Control ECU) |
*2 | Engine Room Relay Block No. 2 |
| *3 | IGCT MAIN Relay | *4 | INV W/P Fuse |
| *5 | Front view of wire harness connector (to Inverter Water Pump Assembly) |
- | - |
| Standard Resistance | ||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Note
Do not apply excessive force when using the probes of the tester to perform the inspection. If excessive force is used, the terminals will be damaged.
Install the INV W/P fuse.
Install the IGCT MAIN relay.
Connect the power management control ECU connector.
Connect the inverter water pump assembly connector.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE INVERTER WATER PUMP ASSEMBLY Click here
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WATER PUMP ASSEMBLY CONNECTOR)
Check the connection of the inverter water pump assembly connector.
| OK |
|---|
| The connector is connected securely and there are no contact problems. |
| NG |
|
CONNECT SECURELY Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (INVERTER WATER PUMP ASSEMBLY CIRCUIT)
Remove the INV W/P fuse from the engine room relay block No. 2.
Disconnect connector A73 from the inverter water pump assembly.
| *1 | Engine Room Relay Block No. 2 |
| *2 | INV W/P Fuse |
| *3 | Front view of wire harness connector (to Inverter Water Pump Assembly) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Note
Do not apply excessive force when using the probes of the tester to perform the inspection. If excessive force is used, the terminals will be damaged.
Install the INV W/P fuse.
Connect the inverter water pump assembly connector.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR Click here |
| OK |
|
REPLACE INVERTER WATER PUMP ASSEMBLY
Replace the inverter water pump assembly Click here.
| NEXT |
|
REPLACE FUSE (INV W/P)
CONNECT SECURELY
Connect the inverter water pump assembly connector securely.
| NEXT |
|
REPLACE FUSE (INV W/P)
REPAIR OR REPLACE HARNESS OR CONNECTOR
Repair or replace the wire harness or connector.
| NEXT |
|
REPLACE FUSE (INV W/P)