HYBRID CONTROL SYSTEM, Diagnostic DTC:P0AFC-150

DTC Code DTC Name
P0AFC-150 Hybrid Battery Pack Sensor Module

DESCRIPTION

The power management control ECU alerts the driver and performs fail-safe control based on error signals sent from the battery smart unit.

DTC NO. INF Code DTC Detection Condition Trouble Area
P0AFC 150 Power source voltage of the battery smart unit drops during precharge.
  • Battery smart unit

  • Wire harness or connector

  • fuse

  • Relay

WIRING DIAGRAM

A01NEYDE01

INSPECTION PROCEDURE

CAUTION:


  • Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

  • After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Tech Tips


  • Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

  • After completing repairs, restart the system (turn the power switch on (READY)) and recheck for DTCs Click here.

PROCEDURE


  1. CHECK FUSE (IGCT NO. 3)


    1. A01NESSE01
      Text in Illustration
      *1 Engine Room Relay Block No. 2
      *2 IGCT No. 3 Fuse

      Remove the IGCT No. 3 fuse from the engine room relay block No. 2.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      IGCT No. 3 fuse Always Below 1 Ω
    3. Install the IGCT No. 3 fuse to the engine room relay block No. 2.


    NG
    OK
  2. CHECK RELAY (IGCT MAIN)


    1. A01NDBGE01
      Text in Illustration
      *1 Engine Room Relay Block No. 2
      *2 IGCT MAIN Relay

      Remove the IGCT MAIN relay from the engine room relay block No. 2.

    2. A01NFEUE17

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Auxiliary battery voltage is applied between terminals 1 and 2 10 kΩ or more
      Auxiliary battery voltage is not applied between terminals 1 and 2 below 1 Ω
    3. Install the IGCT MAIN relay to the engine room relay block No. 2.


    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (IGCT VOLTAGE)

    CAUTION:

    Be sure to wear insulated gloves and protective goggles.


    1. Disconnect the cable from the negative (-) battery terminal.

    2. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    3. Remove the battery cover Click here.

    4. Remove the battery smart unit.

      Tech Tips

      Do not disconnect the battery smart unit connector.

    5. Connect the cable to the negative (-) battery terminal.

    6. Turn the power switch on (IG).

    7. A01NFZCE04
      Text in Illustration
      *1

      Component with harness connected

      (Battery Smart Unit)

      Measure the voltage according to the value(s) in the table below.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

      Tech Tips

      Turning the power switch on (IG) with the service plug grip removed causes an interlock switch system DTC (P0A0D-350) to be set. Use the intelligent tester to clear the DTCs Click here.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      z30-1 (IGCT) - z30-5 (GND) Power switch on (IG) 11 to 14V
    8. Install the battery smart unit Click here.

    9. Install the battery cover.


    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (IGCT MAIN RELAY - BATTERY SMART UNIT)

    CAUTION:

    Be sure to wear insulated gloves and protective goggles.


    1. Disconnect the cable from the negative (-) battery terminal.

    2. A01NDBGE01
      Text in Illustration
      *1 Engine Room Relay Block No. 2
      *2 IGCT MAIN Relay

      Remove the IGCT MAIN relay from the engine room relay block No. 2.

    3. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    4. Remove the battery cover Click here.

    5. Remove the battery smart unit.

      Tech Tips

      Disconnect only the z30 connector of the battery smart unit.

    6. A01NG53E03
      Text in Illustration
      *1

      Rear view of wire harness connector

      (to Battery Smart Unit)

      *2 Engine Room Relay Block No. 2
      *3 IGCT MAIN relay terminal 3

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      IGCT MAIN relay terminal 3 - z30-1 (IGCT) Power switch off Below 1 Ω
    7. Install the battery smart unit Click here.

    8. Install the battery cover.

    9. Install the IGCT MAIN relay to the Engine Room Relay Block No. 2.

    10. Connect the cable to the negative (-) battery terminal.


    NG
    OK