DESCRIPTION
The power management control ECU alerts the driver and performs fail-safe control based on error signals sent from the battery smart unit.
| DTC NO. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0AFC | 150 | Power source voltage of the battery smart unit drops during precharge. |
|
WIRING DIAGRAM
INSPECTION PROCEDURE
CAUTION:
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Tech Tips
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After completing repairs, restart the system (turn the power switch on (READY)) and recheck for DTCs Click here.
PROCEDURE
CHECK FUSE (IGCT NO. 3)
| *1 | Engine Room Relay Block No. 2 |
| *2 | IGCT No. 3 Fuse |
Remove the IGCT No. 3 fuse from the engine room relay block No. 2.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Install the IGCT No. 3 fuse to the engine room relay block No. 2.
| NG |
|
REPLACE FUSE (IGCT NO. 3) |
| OK |
|
CHECK RELAY (IGCT MAIN)
| *1 | Engine Room Relay Block No. 2 |
| *2 | IGCT MAIN Relay |
Remove the IGCT MAIN relay from the engine room relay block No. 2.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
Install the IGCT MAIN relay to the engine room relay block No. 2.
| NG |
|
REPLACE RELAY (IGCT MAIN) |
| OK |
|
CHECK HARNESS AND CONNECTOR (IGCT VOLTAGE)
CAUTION:
Be sure to wear insulated gloves and protective goggles.
Disconnect the cable from the negative (-) battery terminal.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the battery cover Click here.
Remove the battery smart unit.
Tech Tips
Do not disconnect the battery smart unit connector.
Connect the cable to the negative (-) battery terminal.
Turn the power switch on (IG).
| *1 | Component with harness connected (Battery Smart Unit) |
Measure the voltage according to the value(s) in the table below.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Tech Tips
Turning the power switch on (IG) with the service plug grip removed causes an interlock switch system DTC (P0A0D-350) to be set. Use the intelligent tester to clear the DTCs Click here.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Install the battery smart unit Click here.
Install the battery cover.
| NG |
|
| OK |
|
REPLACE BATTERY SMART UNIT Click here
CHECK HARNESS AND CONNECTOR (IGCT MAIN RELAY - BATTERY SMART UNIT)
CAUTION:
Be sure to wear insulated gloves and protective goggles.
Disconnect the cable from the negative (-) battery terminal.
| *1 | Engine Room Relay Block No. 2 |
| *2 | IGCT MAIN Relay |
Remove the IGCT MAIN relay from the engine room relay block No. 2.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the battery cover Click here.
Remove the battery smart unit.
Tech Tips
Disconnect only the z30 connector of the battery smart unit.
| *1 | Rear view of wire harness connector (to Battery Smart Unit) |
| *2 | Engine Room Relay Block No. 2 |
| *3 | IGCT MAIN relay terminal 3 |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Install the battery smart unit Click here.
Install the battery cover.
Install the IGCT MAIN relay to the Engine Room Relay Block No. 2.
Connect the cable to the negative (-) battery terminal.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK AND REPAIR POWER SOURCE CIRCUIT