DESCRIPTION
For a description of MG1, Click here.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0A92 | 261 | Generator magnetic force deterioration or same phase short circuit |
|
INSPECTION PROCEDURE
CAUTION:
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Tech Tips
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
PROCEDURE
CHECK DTC OUTPUT (HV)
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| DTC No. | Relevant Diagnosis |
|---|---|
| P0A1A (all INF codes)*1 | Generator Control Module |
| P0A1B (all INF codes)*1 | Drive Motor "A" Control Module |
| P0A1C (all INF codes)*1 | Drive Motor "B" Control Module |
| P0A1D (all INF codes)*1 | Hybrid Powertrain Control Module |
| P0A60 (all INF codes)*1 | Drive Motor "A" Phase V Current |
| P0A63 (all INF codes)*1 | Drive Motor "A" Phase W Current |
| P0A69 (all INF codes)*1 | Drive Motor "B" Phase V Current |
| P0A6C (all INF codes)*1 | Drive Motor "B" Phase W Current |
| P0A72 (all INF codes)*1 | Generator Phase V Current |
| P0A75 (all INF codes)*1 | Generator Phase W Current |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range/Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A45-669 | Drive Motor "B" Position Sensor Circuit |
| P0A46-671 | Drive Motor "B" Position Sensor Circuit Range/Performance |
| P0A47-670 | Drive Motor "B" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range/Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A51-174 | Drive Motor "A" Current Sensor Circuit |
| P0A55-687 | Drive Motor "B" Current Sensor Circuit |
| P0A78-266, 267, 306, 510, 523, 586 | Drive Motor "A" Inverter Performance |
| P0A79-703, 704 | Drive Motor "B" Current Sensor Circuit |
| P0A7A-203, 344, 522 | Generator Inverter Performance |
| P0A90-509 | Drive Motor "A" Performance |
| P0A91-702 | Drive Motor "B" Performance |
| P0A92-521 | Hybrid Generator Performance |
| P0A94-585, 587, 589, 590 | DC / DC Converter Performance |
| P0AA6 (all INF codes)*1 | Hybrid Battery Voltage System Isolation Fault |
| P3004-132 | Power Cable Malfunction |
| P3233-750 | Short to B+ in Blocking of HV Gate Connection |
Tech Tips
*1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
P0A92-261 may be output due to a malfunction which causes the DTCs in the table above to be output. In this case, first troubleshoot the output DTCs in the table above. Then, perform a reproduction test to check that no DTCs are output.
Turn the power switch off.
| B |
|
GO TO DTC CHART Click here |
| A |
|
SIMULATION TEST
Leave the vehicle for 1 minute with the engine on (with MG1 rotating).
Tech Tips
If the accelerator pedal is depressed with the shift lever in the P position, the engine will start.
Connect the intelligent tester to the DLC3.
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
| B |
|
GO TO DTC CHART Click here |
| A |
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Note
Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.
Check the connection of the low voltage connector of the inverter with converter assembly.
| OK |
|---|
| The connector is connected securely and there are no contact problems. |
Tech Tips
When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.
| NG |
|
CONNECT SECURELY |
| OK |
|
CHECK INVERTER WITH CONVERTER ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter terminal cover from the inverter with converter assembly.
Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.
| Specified Condition |
|---|
| T=8.0 N*m {82 kgf*cm, 71 in.*lbf} |
Note
Make sure that the tightening torque of the bolts is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).
Check for arc marks at the bolts for the generator cable.
| Result | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||
Install the inverter terminal cover.
| B |
|
REPLACE MALFUNCTIONING PARTS |
| C |
|
CONNECT SECURELY |
| A |
|
REPLACE HYBRID VEHICLE GENERATOR ASSEMBLY Click here