| DTC Code | DTC Name |
|---|---|
| P0A0D-350 | High Voltage System Inter-Lock Circuit High |
| P0A0D-351 | High Voltage System Inter-Lock Circuit High |
DESCRIPTION
When the power management control ECU detects that a safety device is operated, it will prohibit hybrid system operation or shut off the system main relay. There are four safety devices in three different locations. The first safety device is located at the service plug grip. The second one is located at the No. 3 wire frame that is connected to the inverter with converter assembly. The third one is located at the inverter terminal cover where the motor and generator cables, rear motor cable and No. 4 engine wire (air conditioning harness) are connected to the inverter with converter assembly. If the service plug grip, inverter terminal cover, or No. 3 wire frame is removed, the interlock signal line will be open. If the vehicle is being driven, this condition will be determined to be an open circuit and the system main relays will not be shut off. If the safety devices are re-installed correctly, the system will return to normal when the power switch is turned on (IG).
| DTC No. | INF Code | DTC Detection Condition | Trouble Are |
|---|---|---|---|
| P0A0D | 350 | Operating any of the safety devices with the vehicle stopped (ILK signal is ON) and turning the power switch on (IG) |
|
| P0A0D | 351 | Interlock signal line opens (ILK signal is ON) while the vehicle is being driven |
WIRING DIAGRAM
INSPECTION PROCEDURE
CAUTION:
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Tech Tips
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
PROCEDURE
CHECK DTC OUTPUT (HV)
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
| B |
|
GO TO DTC CHART Click here |
| A |
|
CLEAR DTC (HV)
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Read and record the DTCs and freeze frame data.
Clear DTCs and freeze frame data.
Turn the power switch off.
| NEXT |
|
RECONFIRM DTC OUTPUT (HV)
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
| B |
|
CHECK CONNECTOR CONNECTION CONDITION (INTERLOCK CIRCUIT) Click here |
| A |
|
CHECK SERVICE PLUG GRIP
CAUTION:
Be sure to wear insulated gloves.
Check if the service plug grip is installed correctly.
Tech Tips
For the removal and installation procedures Click here.
P0A0D-350 is also set if the power switch is turned on (IG) with the service plug grip removed. Confirm the conditions when the malfunction occurred.
| NG |
|
INSTALL PARTS CORRECTLY |
| OK |
|
CHECK INVERTER TERMINAL COVER
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Check if the inverter terminal cover of the inverter with converter assembly is installed correctly.
| OK |
|---|
| The inverter terminal cover is installed correctly. |
| NG |
|
INSTALL PARTS CORRECTLY |
| OK |
|
CHECK NO. 3 WIRE FRAME
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter terminal cover from the inverter with converter assembly.
Check if the No. 3 wire frame g1 is connected correctly.
| OK |
|---|
| The No. 3 wire frame connector is connected correctly. |
Install the inverter terminal cover from the inverter with converter assembly.
| NG |
|
INSTALL PARTS CORRECTLY |
| OK |
|
CHECK POWER MANAGEMENT CONTROL ECU
| *1 | Inverter with converter assembly |
Disconnect connector A79 from the inverter with converter assembly.
Turn the power switch on (IG).
| *1 | Front view of wire harness connector: (to Inverter with Converter Assembly) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
Connect the inverter with converter assembly connector.
| NG |
|
CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER) Click here |
| OK |
|
CHECK INVERTER WITH CONVERTER ASSEMBLY (INTERLOCK)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
| *1 | Inverter with Converter Assembly |
Disconnect connector A79 from the inverter with converter assembly.
| *1 | Component without harness connected: (Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Note
Do not remove the inverter terminal cover.
Connect the inverter with converter assembly connector.
| NG |
|
CHECK INVERTER TERMINAL COVER Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - BODY GROUND)
Install the service plug grip Click here.
| *1 | Inverter with converter assembly |
Disconnect connector A79 from the inverter with converter assembly.
| *1 | Front view of wire harness connector: (to Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Connect the inverter with converter assembly connector.
| NG |
|
CHECK SERVICE PLUG GRIP Click here |
| OK |
|
CHECK CONNECTOR CONNECTION CONDITION (INTERLOCK CIRCUIT)
Check the connections of each connector.
| OK |
|---|
| Dirt or foreign objects have not entered the connection, and there is no evidence of contamination. |
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| B |
|
REPLACE POWER MANAGEMENT CONTROL ECU (for RHD) Click here |
| C |
|
REPAIR OR REPLACE CONNECTOR |
| A |
|
REPLACE POWER MANAGEMENT CONTROL ECU (for LHD) Click here
CHECK SERVICE PLUG GRIP
Remove the service plug grip Click here.
| *1 | Service Plug Grip |
Check the condition of the service plug grip interlock.
| OK |
|---|
| connection, and there is no evidence of contamination. |
Install the service plug grip Click here.
| NG |
|
REPLACE SERVICE PLUG GRIP Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Check that the interlock connector at the service plug grip installation socket is connected correctly.
| OK |
|---|
| The connector is connected correctly. |
| NG |
|
INSTALL PARTS CORRECTLY |
| OK |
|
CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - SERVICE PLUG GRIP))
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
| *1 | Inverter with Converter Assembly |
Disconnect connector A79 from the inverter with converter assembly.
Disconnect connector P46.
| *1 | Front view of wire harness connector: (to Inverter with Converter Assembly) |
| *2 | Front view of wire harness connector: (to Service Plug Grip) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Connect the service plug grip connector.
Connect the inverter with converter assembly connector.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
CHECK INVERTER TERMINAL COVER
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter terminal cover from the inverter with converter assembly.
Check the condition of the inverter terminal cover interlock.
| OK |
|---|
| Dirt or foreign objects have not entered the connection, and there is no evidence of contamination. |
Install the inverter terminal cover from the inverter with converter assembly.
| NG |
|
REPLACE INVERTER TERMINAL COVER Click here |
| OK |
|
CHECK NO. 3 WIRE FRAME (NO. 3 WIRE FRAME CONNECTOR)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter terminal cover from the inverter with converter assembly.
Disconnect the No. 3 wire frame g1 from the inverter with converter assembly.
Check the No. 3 wire frame interlock.
| OK |
|---|
| Dirt or foreign objects have not entered the connection, and there is no evidence of contamination. |
Connect the No. 3 wire frame to the inverter with converter assembly.
Install the inverter terminal cover from the inverter with converter assembly.
| NG |
|
REPLACE NO. 3 WIRE FRAME Click here |
| OK |
|
REPLACE INVERTER WITH CONVERTER ASSEMBLY Click here
CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER)
Turn the power switch off.
| *1 | Inverter with Converter Assembly |
Disconnect connector A79 from the inverter with converter assembly.
| *1 | Rear view of wire harness connector: (to Power Management Control ECU) |
| *2 | Front view of wire harness connector: (to Inverter with Converter Assembly) |
Disconnect connector A80 from the power management control ECU.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
Connect the power management control ECU connector.
Connect the inverter with converter assembly connector.
| B |
|
REPLACE POWER MANAGEMENT CONTROL ECU (for RHD) Click here |
| C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| A |
|
REPLACE POWER MANAGEMENT CONTROL ECU (for LHD) Click here