HYBRID CONTROL SYSTEM, Diagnostic DTC:P0A09-265

DTC Code DTC Name
P0A09-265 DC / DC Converter Status Circuit Low Input

DESCRIPTION

Refer to the description for DTC P0A08-264 Click here.

DTC No. INF Code DTC Detection Condition Trouble Area
P0A09 265 Open or GND short in NODD signal circuit of DC/DC converter
  • Wire harness or connector

  • Inverter with converter assembly

  • Power management control ECU

WIRING DIAGRAM

Refer to the wiring diagram for DTC P0A08-264 Click here.

INSPECTION PROCEDURE

CAUTION:


  • Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

  • After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Tech Tips

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

PROCEDURE


  1. CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

      Note

      Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.

      A01NHWR
    2. Check the connection of the low voltage connector of the inverter with converter assembly.

      OK
      The connector is connected securely and there are no contact problems.

      Tech Tips

      When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.


    NG
    OK
  2. CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)


    1. Check the connections of the power management control ECU connectors.

      A01NF3IE01
      Text in Illustration
      *1 for LHD *2 for RHD
      OK
      The connectors are connected securely and there are no contact problems.

    NG
    OK
  3. CHECK POWER MANAGEMENT CONTROL ECU

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Turn the power switch off.

    3. Disconnect the A79 connector from the inverter with converter assembly.

    4. A01NFV3E09
      Text in Illustration
      *1

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A79-24 (NODD) - Body ground Power switch off 120 to 140 kΩ
    5. Connect the inverter with converter assembly connector.


    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER - POWER MANAGEMENT CONTROL ECU)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the A79 connector from the inverter with converter assembly.

    3. Disconnect the A80 connector from the power management control ECU.

    4. A01NEUQE01
      Text in Illustration
      *1

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      *2

      Rear view of wire harness connector

      (to Power Management Control ECU)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A79-24 (NODD) - A80-21 (NODD) Power switch off Below 1 Ω
      A79-24 (NODD) or A80-21 (NODD) - Body ground and other terminals Power switch off 10 kΩ or higher
      Result
      Result Proceed to
      OK (for LHD) A
      OK (for RHD) B
      NG C
    5. Connect the inverter with converter assembly connector.

    6. Connect the power management control ECU connector.


    B
    C
    A