INSTALL NO. 2 OXYGEN SENSOR
| *1 | Fulcrum Length 30 mm |
Using SST, install the No. 2 oxygen sensor to the front exhaust pipe assembly.
Note
The "with SST" torque value is effective when using SST with a fulcrum length of 30 mm (1.18 in.).
The "with SST" torque value is effective when using a torque wrench with a fulcrum length of 300 mm (11.81 in.) Click here.
The "with SST" torque value is effective when SST is parallel to the torque wrench.
Install the wire harness clamp bracket.
INSTALL FRONT EXHAUST PIPE ASSEMBLY
Install a new gasket to the front exhaust pipe assembly.
Install the front exhaust pipe assembly with the 2 nuts and 2 bolts (B).
Tighten the bolt (A).
Connect the 2 clamps and No. 2 oxygen sensor connector (for Bank 2 Sensor 2).
INSTALL NO. 3 FRONT EXHAUST PIPE SUB-ASSEMBLY
| *1 | No. 3 Front Exhaust Pipe Sub-assembly |
| *2 | Gasket |
| *3 | Wooden Block |
Using a plastic hammer and wooden block, tap in a new gasket until its surface is flush with the No. 3 front exhaust pipe sub-assembly.
Note
Be sure to install the gasket in the correct orientation.
Do not reuse the gasket.
Do not damage the gasket.
Do not push in the gasket by using the exhaust pipe when connecting it.
Install 2 new gaskets to the No. 3 front exhaust pipe sub-assembly.
Install the No. 3 front exhaust pipe sub-assembly with the 2 bolts and 2 nuts.
Using a vernier caliper, measure the free length of the compression springs.
| Minimum length |
|---|
| 41.5 mm (1.64 in.) |
If the free length is less than the minimum, replace the compression spring.
Install the front No. 3 exhaust pipe sub-assembly with the 2 bolts and 2 compression springs.
INSTALL OXYGEN SENSOR
| *1 | Fulcrum Length 30 mm |
| *2 | Fulcrum Length 300 mm |
Using SST, install the oxygen sensor to the center exhaust pipe assembly.
Note
The "with SST" torque value is effective when using SST with a fulcrum length of 30 mm (1.18 in.).
The "with SST" torque value is effective when using a torque wrench with a fulcrum length of 300 mm (11.81 in.) Click here.
The "with SST" torque value is effective when SST is parallel to the torque wrench.
Connect the wire harness clamp.
Connect the 2 wire harness clamps and oxygen sensor connector (for Bank 1 Sensor 2).
INSPECT FOR EXHAUST GAS LEAK
INSTALL FRONT FLOOR COVER LH
| *1 | Bolt |
| *2 | Screw |
Connect the 2 clips (B).
Install the front floor cover LH with the 2 screws and 4 bolts.
Install the clip (A).