SFI SYSTEM (w/ EGR System), Diagnostic DTC:P0230

DTC Code DTC Name
P0230 Fuel Pump Primary Circuit

DESCRIPTION


A01NE71E02
DTC No. DTC Detection Condition Trouble Area
P0230

Open or short in F/PMP relay circuit

(1 trip detection logic)


  • Open or short in F/PMP relay circuit

  • F/PMP relay

  • ECM

WIRING DIAGRAM

A01NDQQE02

INSPECTION PROCEDURE

Tech Tips

This troubleshooting procedure is based on the premise that the engine can start. If the engine cannot start, proceed to Problem Symptoms Table Click here.

PROCEDURE


  1. INSPECT F/PMP RELAY


    1. A01NHIDE10

      Remove the F/PMP relay from the engine room relay block.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 4 No battery voltage applied to terminals 1 and 2 Below 1 Ω
      3 - 4 Battery voltage applied to terminals 1 and 2 10 kΩ or higher
      3 - 5 No battery voltage applied to terminals 1 and 2 10 kΩ or higher
      3 - 5 Battery voltage applied to terminals 1 and 2 Below 1 Ω
    3. Reinstall the F/PMP relay.


    NG
    OK
  2. CHECK TERMINAL VOLTAGE (F/PMP RELAY)


    1. A01NEUKE01
      Text in Illustration
      *1 Engine Room Relay Block

      Remove the F/PMP relay from the engine room relay block.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      F/PMP relay terminal 2 - Body ground Cranking 11 to 14 V
      F/PMP relay terminal 2 - Body ground Power switch on (IG) 0 to 3 V
    3. Reinstall the F/PMP relay.


    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (F/PMP RELAY - ECM)


    1. Remove the F/PMP relay from the engine room relay block.

      A01NEEUE02
    2. Disconnect the ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Condition Specified Condition
      F/PMP relay terminal 1 - A76-29 (FPR) Always Below 1 Ω
      Standard Resistance (Check for Short)
      Tester Connection Condition Specified Condition
      F/PMP relay terminal 1 or A76-29 (FPR) - Body ground Always 10 kΩ or higher
      Text in Illustration
      *1

      Front view of wire harness connector

      (to ECM)

      *2 Engine Room Relay Block
    4. Reconnect the ECM connector.

    5. Reinstall the F/PMP relay.


    NG
    OK