HYBRID / BATTERY CONTROL SERVICE DATA

Reserve Tank Cap (for Inverter)
Item Specified Condition
Standard valve (for brand-new cap)

93.3 to 122.7 kPa (1.0 to 1.3 kgf/cm2, 13.5 to 17.8 psi)

Minimum standard valve (for used cap)

78.5 kPa (0.8 kgf/cm2, 11.4 psi)

Relay
Item Tester Connection Specified Condition
No. 1 circuit breaker sensor 1 (SIF-) - 2 (SIF+) 0.65 to 1.0 kΩ at 20°C (68°F)

IGCT relay

Resistance

3 - 5

10 kΩ or higher

(When battery voltage is not applied between terminals 1 and 2)

3 - 5

Below 1 Ω

(When battery voltage is applied between terminals 1 and 2)

Hybrid Battery Junction Block

SMRB

Resistance

4 (SMRB) - 2 (GND) 19.0 to 35.5 Ω (at -40°C (-40°F) to 80°C (176°F))

SMRG

Resistance

1 (SMRG) - 2 (GND) 19.0 to 35.5 Ω (at -40°C (-40°F) to 80°C (176°F))

SMRP

Resistance

3 (SMRP) - 2 (GND) 141 to 212 Ω (at -40°C (-40°F) to 80°C (176°F))

Precharge

resistor

- 28.5 to 31.5 Ω
Electric vehicle fuse - Below 1 Ω
Electric Vehicle Battery Plug Assembly
Electric vehicle battery plug assembly

Lead wire 1 - grip terminal

Lead wire 1 - grip terminal

Below 1 Ω

Below 1 Ω

Service Plug Grip