READ DATA LIST
Tech Tips
Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
Note
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Turn the power switch off.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Chassis / Tilt & Telescopic / Data List.
According to the display on the intelligent tester, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Tilt Position | Current tilt position data/ Min.: 0 Max.: 65535 |
28672 to 36864 | - |
| Telesco Position | Current telescopic position data/ Min.: 0 Max.: 65535 |
28672 to 36864 | - |
| Tilt Return Position | Memorized tilt return position data/ Min.: 0 Max.: 65535 |
28672 to 36864 | - |
| Telesco Return Position | Memorized telescopic return position data/ Min.: 0 Max.: 65535 |
28672 to 36864 | - |
| Tilt Memory Pos 1 | Tilt data of memory position 1/ Min.: 0 Max.: 65535 |
28672 to 36864 | - |
| Telesco Memory Pos 1 | Telescopic data of memory position 1/ Min.: 0 Max.: 65535 |
28672 to 36864 | - |
| Tilt Memory Pos 2 | Tilt data of memory position 2/ Min.: 0 Max.: 65535 |
28672 to 36864 | - |
| Telesco Memory Pos 2 | Telescopic data of memory position 2/ Min.: 0 Max.: 65535 |
28672 to 36864 | - |
| Tilt Memory Pos 3 | Tilt data of memory position 3/ Min.: 0 Max.: 65535 |
28672 to 36864 | - |
| Telesco Memory Pos 3 | Telescopic data of memory position 3/ Min.: 0 Max.: 65535 |
28672 to 36864 | - |
| Tilt Up Limit | Uppermost tilt position/ Not Mem or Mem |
Not Mem: Position not memorized Mem: Position memorized |
- |
| Tilt Up Limit Position | Uppermost tilt position data/ Min.: 0 Max.: 65535 |
28672 to 36864 | - |
| Tilt Down Limit | Lowermost tilt position/ Not Mem or Mem |
Not Mem: Position not memorized Mem: Position memorized |
- |
| Tilt Down Limit Position | Lowermost tilt position data/ Min.: 0 Max.: 65535 |
28672 to 36864 | - |
| Telesco Short Limit | Shortest telescopic position/ Not Mem or Mem |
Not Mem: Position not memorized Mem: Position memorized |
- |
| Telesco Short Limit Pos | Shortest telescopic position data/ Min.: 0 Max.: 65535 |
28672 to 36864 | - |
| Telesco Long Limit | Longest telescopic position/ Not Mem or Mem |
Not Mem: Position not memorized Mem: Position memorized |
- |
| Telesco Long Limit Pos | Longest telescopic position data/ Min.: 0 Max.: 65535 |
28672 to 36864 | - |
| Tilt Up Switch | Input state of tilt up by manual switch/ ON or OFF |
ON: Tilt up activated by manual switch OFF: Tilt up not activated by manual switch |
- |
| Tilt Up SW(CAN) | Input state of tilt up by manual switch/ ON or OFF |
ON: Tilt up activated by manual switch OFF: Tilt up not activated by manual switch |
- |
| Tilt Down Switch | Input state of tilt down by manual switch/ ON or OFF |
ON: Tilt down activated by manual switch OFF: Tilt down not activated by manual switch |
- |
| Tilt Down SW(CAN) | Input state of tilt down by manual switch/ ON or OFF |
ON: Tilt down activated by manual switch OFF: Tilt down not activated by manual switch |
- |
| Telesco Short Switch | Input state of telescopic short by manual switch/ ON or OFF |
ON: Telescopic short activated by manual switch OFF: Telescopic short not activated by manual switch |
- |
| Telesco Short SW(CAN) | Input state of telescopic short by manual switch/ ON or OFF |
ON: Telescopic short activated by manual switch OFF: Telescopic short not activated by manual switch |
- |
| Telesco Long Switch | Input state of telescopic long by manual switch/ ON or OFF |
ON: Telescopic long activated by manual switch OFF: Telescopic long not activated by manual switch |
- |
| Telesco Long SW(CAN) | Input state of telescopic long by manual switch/ ON or OFF |
ON: Telescopic long activated by manual switch OFF: Telescopic long not activated by manual switch |
- |
| T&T Manual SW Data | Voltage data of manual switch/ Min.: 0 V Max.: 4.99 V |
Neutral position: Below 0.2 V Tilt up: 1.67 to 2.13 V Tilt down: 0.54 to 0.74 V Telescopic contract: 1.08 to 1.40 V Telescopic extend: 2.22 to 2.77 V |
- |
| S/B Mem 1 | Tilt and telescopic memory position 1/ Not Mem or Mem |
Not Mem: Position not memorized Mem: Position memorized |
- |
| S/B Mem 2 | Tilt and telescopic memory position 2/ Not Mem or Mem |
Not Mem: Position not memorized Mem: Position memorized |
- |
| S/B Mem 3 | Tilt and telescopic memory position 3/ Not Mem or Mem |
Not Mem: Position not memorized Mem: Position memorized |
- |
| T&T Autoaway Function | Auto away/return function/ ON or OFF |
ON: Auto away/return function allowed OFF: Auto away/return function prohibited |
- |
| Power Source Voltage | Voltage data of power supply/ Min.: 0 V Max.: 19.99 V |
11 to 14 V | - |
| Freeze Speed Info | Vehicle speed data/ Min.: 0 km/h (0 mph) Max.: 255 km/h (158 mph) |
Stop → Drive → Stop | 0 km/h (0 mph) → Same speed as indicated on speedometer → 0 km/h (0 mph) |
| IG Switch (CAN) | Communication state of power switch/ ON or OFF |
ON: Communication normal OFF: Communication interrupted |
- |
| IG Switch | Input state of power switch/ ON or OFF |
ON: Input signal normal OFF: Input signal interrupted |
- |
| Receive from Meter | Communication state of combination meter signal/ OK or Interpt |
OK: Communication normal Interpt: Communication interrupted |
- |
| Receive from Seat ECU | Communication state of position control ECU signal/ OK or Interpt |
OK: Communication normal Interpt: Communication interrupted |
- |
| Receive from Combi | Communication state of combination switch ECU signal/ OK or Interpt |
OK: Communication normal Interpt: Communication interrupted |
- |
| J/B | Communication state of main body ECU signal/ OK or Interpt |
OK: Communication normal Interpt: Communication interrupted |
- |
| Driver Information 1 | Driver Information 1/ Not Mem or Mem |
Not Mem: Position not memorized Mem: Position memorized |
- |
| Driver 1 Tilt Mem | Driver tilt memory position 1/ Min.: 0 Max.: 65535 |
28672 to 36864 | - |
| Driver 1 Telesco Mem | Driver telescopic memory position 1/ Min.: 0 Max.: 65535 |
28672 to 36864 | - |
| Driver Information 2 | Driver Information 2/ Not Mem or Mem |
Not Mem: Position not memorized Mem: Position memorized |
- |
| Driver 2 Tilt Mem | Driver tilt memory position 2/ Min.: 0 Max.: 65535 |
28672 to 36864 | - |
| Driver 2 Telesco Mem | Driver telescopic memory position 2/ Min.: 0 Max.: 65535 |
28672 to 36864 | - |
| Driver Information 3 | Driver Information 3/ Not Mem or Mem |
Not Mem: Position not memorized Mem: Position memorized |
- |
| Driver 3 Tilt Mem | Driver tilt memory position 3/ Min.: 0 Max.: 65535 |
28672 to 36864 | - |
| Driver 3 Telesco Mem | Driver telescopic memory position 3/ Min.: 0 Max.: 65535 |
28672 to 36864 | - |
| Handle Position | Steering wheel position signal/ Away or Return |
Away: Steering wheel in away position Return: Steering wheel in return position (Except remote start) |
- |
| The Number of DTCs | Number of stored DTCs/ Min.: 0 Max.: 255 |
Actual number of stored DTCs | - |
ACTIVE TEST
Tech Tips
Using the intelligent tester to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Turn the power switch off.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Chassis / Tilt & Telescopic / Active Test.
According to the display on the intelligent tester, perform the Active Test.
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Tilt Operation | Tilt operation | UP/DOWN | - |
| Telesco Operation | Telescopic operation | LONG/SHORT | - |