КЛАПАН ПРИНУДИТЕЛЬНОЙ ВЕНТИЛЯЦИИ КАРТЕРА ПРОВЕРКА


  1. INSPECT VENTILATION VALVE SUB-ASSEMBLY


    1. Check the operation.


      1. A01183UE01

        Install the hose to the cylinder head side of the ventilation valve.

      2. Check that the air flows smoothly when air is applied from the cylinder head side.

        OK
        Air flows

        CAUTION:


        • Do not suck air through the valve.

        • Petroleum substances inside the valve are hazardous to your health.

        If the result is not as specified, replace the ventilation valve sub-assembly.

      3. Remove the hose.

      4. A0119CLE01

        Install the hose to the manifold side of the ventilation valve.

      5. Check that air does not flow when air is applied from the manifold side.

        OK
        Air does not flow.

        CAUTION:


        • Do not suck air through the valve.

        • Petroleum substances inside the valve are hazardous to your health.

        If the result is not as specified, replace the ventilation valve sub-assembly.

      6. Remove the hose from the ventilation valve sub-assembly.