DESCRIPTION
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| 010 | Battery voltage is 14 V or more for 20 seconds or more. |
|
| 011 | Battery voltage is 11 V or less for 20 seconds or more. |
WIRING DIAGRAM
INSPECTION PROCEDURE
Note
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Tech Tips
Before performing the following procedure, check the battery and generator and confirm that they are operating normally.
PROCEDURE
CHECK HARNESS AND CONNECTOR (POWER HEATER ECU (COMBUSTION HEATER ASSEMBLY) - BODY GROUND)
| *1 | Front view of wire harness connector (to Power Heater ECU (Combustion Heater Assembly)) |
Disconnect the A45 power heater ECU (combustion heater assembly) connector.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Reconnect the power heater ECU (combustion heater assembly) connector.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE COMBUSTION HEATER ASSEMBLY Click here