READ DATA LIST
Tech Tips
Using an intelligent tester to read the Data List allows the values or states of switches, sensor, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may by discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
Note
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Data List.
According to the display on tester, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Evaporator Temp Thermistor | Evaporator fin thermistor / Min.: -29.7°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual evaporator temperature is displayed | - |
| Evaporator Fin Thermistor | Evaporator fin thermistor / Min.: -29.7°C (-21.46°F), Max.: 59.55°C (139.19°F) |
Actual evaporator temperature is displayed | Open in circuit: -29.7°C (- 21.46°F) Short in circuit: 59.55°C (139.19°F) |
| Evaporator Target Temp | Evaporator target temperature / Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Evaporator target temperature displayed | - |
| Engine Coolant Temp | Engine coolant temperature / Min.: 1.3°C (34.34°F), Max.: 90.55°C (194.99°F) |
Actual engine coolant temperature is displayed while engine is warmed up | - |
| Regulator Pressure Sensor | Regulator pressure sensor / Min.: 0.45668 MPaG Max.: 3.29437 MPaG |
Actual refrigerant pressure is displayed | - |
| Regulator Control Current | Refrigerant control current / Min.: 0 A, Max.: 0.997 A |
Value changes between 0 A and 0.997 A in accordance with compressor and magnetic clutch operation | - |
| Electric Heater Count | Number of electric heaters operating / Min.: 0, Max.: 3 |
- | - |
| Flow Sensor | Flow sensor / Min.: 0.0 V, Max.: 5.0 V |
Flow sensor voltage displayed | Open circuit: 4.7 V or more Short circuit: 0.3 V or less |
| Number of Trouble Codes | Number of trouble codes / Min.: 0, Max.: 255 |
Number of DTCs will be displayed | - |
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Ambient Temperature | Ambient temperature / Min.: -40°C (-40°F) Max.: 87.5°C (189.5°F) |
Actual ambient temperature is displayed | - |
PERFORM ACTIVE TEST
Tech Tips
Using the intelligent tester to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Active Test.
According to the display on tester, perform the Active Test.
| Tester Display | Test Part | Control Range | Normal Condition |
|---|---|---|---|
| Magnetic Clutch Relay | Magnetic clutch relay | ON, OFF | - |
| Heater Active Level | Heater level | Min.: 0, Max.: 3 | - |