AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) IG Power Source Circuit

DESCRIPTION

This is the main power source supplied to the air conditioning amplifier when the ignition switch is ON. This power source is used for operating components, such as the air conditioning amplifier and servo motors.

WIRING DIAGRAM

A011B87E01

INSPECTION PROCEDURE

Note

Inspect the fuses for circuits related to this system before performing the following inspection procedure.

PROCEDURE


  1. INSPECT AIR CONDITIONING AMPLIFIER


    1. A0117MXE24
      Text in Illustration
      *1

      Rear view of wire harness connector

      (to Air Conditioning Amplifier)

      Disconnect the D15 air conditioning amplifier connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      D15-1 (IG+) - D15-14 (GND) Ignition switch ON 11 to 14 V
    3. Reconnect the air conditioning amplifier connector.

      Result
      Result Proceed to
      OK A

      NG

      (w/o Stop and Start System)

      B

      NG

      (w/ Stop and Start System)

      C

    B
    C
    A
  2. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - BODY GROUND)


    1. A0117MXE25
      Text in Illustration
      *1

      Rear view of wire harness connector

      (to Air Conditioning Amplifier)

      Disconnect the D15 air conditioning amplifier connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      D15-14 (GND) - Body ground Always Below 1 Ω
    3. Reconnect the air conditioning amplifier connector.


    NG
    OK