DESCRIPTION
In this circuit, the compressor receives a refrigerant compression demand signal from the air conditioning amplifier.
Based on this signal, the compressor changes the degree of refrigerant compression.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1451/51 | Open or short in solenoid of externally changeable compressor circuit |
|
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
READ VALUE USING INTELLIGENT TESTER (REGULATOR CONTROL CURRENT)
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Data List.
According to the display on the intelligent tester, read the Data List.
| Tester Display | Measurement Item/Display (Range) | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Regulator Control Current | Regulator control current / Min.: 0 A Max.: 0.997 A |
Value changes between 0 A and 0.997 A in accordance with compressor and pulley operation | - |
| OK |
|---|
| The display is as specified in the normal condition column. |
| Result | Proceed to |
|---|---|
| NG | A |
| OK (When troubleshooting according to the Problem Symptoms Table) | B |
| OK (When troubleshooting according to the DTC output) | C |
| B |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| C |
|
REPLACE AIR CONDITIONING AMPLIFIER Click here |
| A |
|
INSPECT AIR CONDITIONING COMPRESSOR
| *1 | Component without harness connected (Air Conditioning Compressor) |
Disconnect the B33 air conditioning compressor connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Reconnect the air conditioning compressor connector.
| Result | Proceed to |
|---|---|
| OK | A |
| NG (for 1KR-FE) | B |
| NG (for 1ND-TV) | C |
| B |
|
REPLACE AIR CONDITIONING COMPRESSOR Click here |
| C |
|
REPLACE AIR CONDITIONING COMPRESSOR Click here |
| A |
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONING COMPRESSOR - AIR CONDITIONING AMPLIFIER)
| *1 | Front view of wire harness connector (to Air Conditioning Compressor) |
| *2 | Rear view of wire harness connector (to Air Conditioning Amplifier) |
Disconnect the B33 air conditioning compressor connector.
Disconnect the D15 air conditioning amplifier connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Reconnect the air conditioning compressor connector.
Reconnect the air conditioning amplifier connector.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONING COMPRESSOR - BODY GROUND)
| *1 | Front view of wire harness connector (to Air Conditioning Compressor) |
Disconnect the B33 air conditioning compressor connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Reconnect the air conditioning compressor connector.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE AIR CONDITIONING AMPLIFIER Click here