CUSTOMIZING FUNCTION WITH THE INTELLIGENT TESTER
Tech Tips
The following items can be customized.
Note
When the customer requests a change in a function, first make sure that the function can be customized.
Be sure to make a note of the current settings before customizing.
When troubleshooting a function, first make sure that the function is set to the default setting.
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Main Body or Illuminated Entry / Utility / Customize
Select the setting by referring to the table below.
| Display | Default | Content | Setting |
|---|---|---|---|
| Wireless Door Lock | ON | ON/OFF of wireless door lock function. | ON or OFF |
| Hazard Answer Back | ON | When LOCK switch on transmitter pressed, all hazard warning lights illuminate once. When UNLOCK switch pressed, all hazard warning lights illuminate twice. | ON or OFF |
| Open Door Warning | ON | If door is not completely closed and transmitter LOCK switch is pressed, this function sounds a buzzer for 10 seconds. | ON or OFF |
| Auto Lock Time | 30s | This function controls amount of time from unlocking doors to automatic re-locking function. | 30 s, 60 s or 120 s |
| Wireless Buzzer Volume | Level 7 | This function changes the wireless buzzer volume. | Level 0, Level 1, Level 2, Level 3, Level 4, Level 5, Level 6 or Level 7 |
| Display | Default | Content | Setting |
|---|---|---|---|
| Lighting Time | 15 s | Changes the lighting time after closing all of the doors. (It will quickly fade out in case of turning the engine switch from off to on (ACC or IG).) | 7.5 s, 15 s or 30 s |