CAN COMMUNICATION SYSTEM Air Conditioning Amplifier Communication Stop Mode

DESCRIPTION

Detection Item Symptom Trouble Area
Air Conditioning Amplifier Communication Stop Mode
  • "Air Conditioner" not displayed on "Communication Bus Check" screen of intelligent tester

  • Applies to "Air Conditioning Amplifier Communication Stop Mode" in "DTC combination table"


  • Power source circuit of air conditioning amplifier assembly

  • Air conditioning amplifier assembly branch wire or connector

  • Air conditioning amplifier assembly

WIRING DIAGRAM

A011B16E01

INSPECTION PROCEDURE

Note


  • Inspect the fuses for circuit related to this system before performing the following inspection procedure.

  • Turn the ignition switch off before measuring the resistances of the CAN main wire and the CAN branch wire.

  • After the ignition switch is turned off, check that the key reminder warning system and light reminder warning system are not in operation.

  • Before measuring the resistance, leave the vehicle as is for at least 1 minute and do not operate the ignition switch, any other switches or the doors. If doors need to be opened in order to check connectors, open the doors and leave them open.

Tech Tips

Operating the ignition switch, any switches or any doors triggers related ECU and sensor communication with the CAN, which causes resistance variation.

PROCEDURE


  1. SYSTEM CHECK


    1. Check the vehicle specifications.

      Result
      Result Proceed to
      for automatic air conditioning system A
      for manual air conditioning system B

    B
    A
  2. CHECK FOR OPEN IN CAN BUS WIRE (AIR CONDITIONING AMPLIFIER ASSEMBLY BRANCH WIRE)


    1. A0119A9E01
      Text in Illustration
      *1

      Front view of wire harness connector

      (to Air Conditioning Amplifier Assembly)

      Turn the ignition switch off.

    2. Disconnect the D15 air conditioning amplifier assembly connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      D15-11 (TX+) - D15-12 (TX-) Ignition switch off 54 to 69 Ω
    4. Reconnect the air conditioning amplifier assembly connector.


    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - BATTERY AND BODY GROUND)


    1. A0119A9E02
      Text in Illustration
      *1

      Front view of wire harness connector

      (to Air Conditioning Amplifier Assembly)

      Disconnect the D15 air conditioning amplifier assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      D15-14 (GND) - Body ground Always Below 1 Ω
    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      D15-1 (IG+) - Body ground Ignition switch ON 11 to 14 V
    4. Reconnect the air conditioning amplifier assembly connector.


    NG
    OK
  4. CHECK FOR OPEN IN CAN BUS WIRE (AIR CONDITIONING AMPLIFIER ASSEMBLY BRANCH WIRE)


    1. A011ALKE01
      Text in Illustration
      *1

      Front view of wire harness connector

      (to Air Conditioning Amplifier Assembly)

      Turn the ignition switch off.

    2. Disconnect the D16 air conditioning amplifier assembly connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      D16-8 (TX+) - D16-9 (TX-) Ignition switch off 54 to 69 Ω
    4. Reconnect the air conditioning amplifier assembly connector.


    NG
    OK
  5. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - BATTERY AND BODY GROUND)


    1. A011ALKE02
      Text in Illustration
      *1

      Front view of wire harness connector

      (to Air Conditioning Amplifier Assembly)

      Disconnect the D16 air conditioning amplifier assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      D16-24 (GND) - Body ground Always Below 1 Ω
    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      D16-14 (IG+) - Body ground Ignition switch ON 11 to 14 V
    4. Reconnect the air conditioning amplifier assembly connector.


    NG
    OK