LIN COMMUNICATION SYSTEM, Diagnostic DTC:B1206

DTC Code DTC Name
B1206 P/W Master Switch Communication Stop

DESCRIPTION

The main body ECU stores a DTC when communication with the power window regulator master switch assembly is interrupted for 10 seconds or more.

DTC No. DTC Detection Condition Trouble Area
B1206 Communication between power window regulator master switch assembly and main body ECU interrupted for 10 seconds or more, or communication wire malfunction.
  • Harness or connector

  • Power window regulator master switch assembly

  • Main body ECU

  • Instrument panel junction block assembly

WIRING DIAGRAM

A011861E01

INSPECTION PROCEDURE

Tech Tips


  • When using the intelligent tester, repeatedly turn either front door courtesy light switch off-and-on at intervals of 1.5 seconds or less, until communication between the intelligent tester and vehicle begins.

  • When the main body ECU has been replaced with a new part, or when the battery negative terminal is reconnected, the ignition switch condition will be ON. Also, when the battery has been removed and installed, the condition will be the same as it was before the battery was disconnected.

Note

Inspect the fuses for this circuit before starting this inspection procedure.

PROCEDURE


  1. CLEAR DTC


    1. Clear DTCs Click here.


    NEXT
  2. CHECK FOR DTC


    1. Check for DTCs Click here.

      Result
      Result Proceed to
      DTC B1206 is output A
      DTC B1206 and B2325 is output B

      Tech Tips

      When both B1206 and B2325 are output at the same time, troubleshoot B2325 first.


    B
    A
  3. CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL J/B - MASTER SWITCH)


    1. A011948E01
      Text in Illustration
      *1

      Front view of wire harness connector

      (to Instrument Panel Junction Block Assembly)

      *2

      Front view of wire harness connector

      (to Power Window Regulator Master Switch Assembly)

      *3 for RHD
      *4 for LHD

      Disconnect the 3C instrument panel junction block assembly connector.

    2. Disconnect the E1 or F1 power window regulator master switch assembly connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for RHD
      Tester Connection Condition Specified Condition
      3C-28 (LIN2) - E1-17 (LIN1) Always Below 1 Ω
      E1-17(LIN1) - Body ground Always 10 KΩ or higher
      for LHD
      Tester Connection Condition Specified Condition
      3C-28 (LIN2) - F1-17 (LIN1) Always Below 1 Ω
      F1-17(LIN1) - Body ground Always 10 KΩ or higher
    4. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      for RHD
      Tester Connection Condition Specified Condition
      E1-17 (LIN1) - Body ground Always Below 0.5 V
      for LHD
      Tester Connection Condition Specified Condition
      F1-17 (LIN1) - Body ground Always Below 0.5 V
    5. Reconnect the instrument panel junction block assembly connector.

    6. Reconnect the power window regulator master switch connector.


    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (MASTER SWITCH - BATTERY AND BODY GROUND)


    1. A0119RIE01
      Text in Illustration
      *1

      Front view of wire harness connector

      (to Power Window Regulator Master Switch Assembly)

      *2 for RHD
      *3 for LHD

      Disconnect the E1 or F1 power window regulator master switch assembly connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      for RHD
      Tester Connection Condition Specified Condition
      E1-11 (B) - Body ground Always 11 to 14 V
      for LHD
      Tester Connection Condition Specified Condition
      F1-11 (B) - Body ground Always 11 to 14 V
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for RHD
      Tester Connection Condition Specified Condition
      E1-12 (GND) - Body ground Always Below 1 Ω
      for LHD
      Tester Connection Condition Specified Condition
      F1-12 (GND) - Body ground Always Below 1 Ω
    4. Reconnect the power window regulator master switch assembly connector.


    NG
    OK
  5. REPLACE POWER WINDOW REGULATOR MASTER SWITCH NORMAL ONE


    1. Replace the power window regulator master switch assembly with a normally functioning part Click here.

    2. Clear DTCs Click here.


    NEXT
  6. RECONFIRM DTC OUTPUT


    1. Recheck for DTCs Click here.

      Result
      Result Proceed to
      DTC B1206 is not output A
      DTC B1206 is output B

    B
    A
  7. INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY

    A01179UE04
    Text in Illustration
    *1

    Component without harness connected

    (Instrument Panel Junction Block Assembly)


    1. Remove the instrument panel junction block assembly Click here.

    2. Remove the main body ECU from the instrument panel junction block assembly Click here.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3C-28 (LIN2) - 3F-16 (LIN2) Always Below 1 Ω
      3C-28 (LIN2) - Body ground Always 10 KΩ or higher
    4. Reinstall the main body ECU Click here.

    5. Reinstall the instrument panel junction block assembly Click here.


    NG
    OK