DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
REMOVE FAN & GENERATOR V BELT
Remove the fan and generator V belt Click here.
REMOVE AIR CLEANER CAP SUB-ASSEMBLY
| *1 | Wire harness clamp |
| *2 | Clamp |
Disconnect the connector and 2 wire harness clamps.
Loosen the hose clamp and separate the air cleaner hose.
Disengage the 2 clamps and 2 claws and remove the air cleaner cap.
REMOVE AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY
Remove the air cleaner filter element.
REMOVE AIR CLEANER CASE SUB-ASSEMBLY
Remove the 3 bolts and the air cleaner case.
REMOVE GENERATOR ASSEMBLY
Remove the terminal cap.
Disconnect the connector.
Remove the nut and separate the terminal B.
Remove bolts and nut.
Using a "TORX" socket wrench (E10), remove the stud bolt.
Remove bolt and the generator.