GENERATOR REMOVAL


  1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

  2. REMOVE FAN & GENERATOR V BELT


    1. Remove the fan and generator V belt Click here.

  3. REMOVE AIR CLEANER CAP SUB-ASSEMBLY


    1. A011AQSE01
      Text in Illustration
      *1 Wire harness clamp
      *2 Clamp

      Disconnect the connector and 2 wire harness clamps.

    2. Loosen the hose clamp and separate the air cleaner hose.

    3. Disengage the 2 clamps and 2 claws and remove the air cleaner cap.

  4. REMOVE AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY


    1. A0118L6

      Remove the air cleaner filter element.

  5. REMOVE AIR CLEANER CASE SUB-ASSEMBLY


    1. A011AXX

      Remove the 3 bolts and the air cleaner case.

  6. REMOVE GENERATOR ASSEMBLY

    A0117QR

    1. Remove the terminal cap.

    2. Disconnect the connector.

    3. Remove the nut and separate the terminal B.

    4. A0119UK

      Remove bolts and nut.

    5. Using a "TORX" socket wrench (E10), remove the stud bolt.

    6. A0118FD

      Remove bolt and the generator.