GENERATOR REMOVAL


  1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

  2. REMOVE FAN AND GENERATOR V BELT

    Click here

  3. REMOVE GENERATOR ASSEMBLY


    1. A0119FE

      Remove the terminal cap.

    2. Disconnect the connector and 2 harness clamps.

    3. Remove the nut and terminal B.

    4. A011736

      Remove the 2 bolts and 2 brackets.

    5. A0117T0

      Remove the 2 bolts and fan belt adjusting bar.

    6. A01182A

      Remove the bolt and generator assembly.