| DTC Code | DTC Name |
|---|---|
| P0715 | Input/Turbine Speed Sensor "A" Circuit |
| P0717 | Input/Turbine Speed Sensor "A" Circuit No Signal |
DESCRIPTION
The ECM receives a signal from the turbine speed sensor (transmission revolution sensor (NT)) installed in the continuously variable transaxle to control the lock up engagement pressure and forward clutch pressure.
The transmission revolution sensor (NT) detects the continuously variable transaxle input shaft speed and sends it to the ECM.
| DTC No. | DTC Detection Condition
|
Trouble Area |
|---|---|---|
| P0715 |
|
|
| P0717 |
|
|
MONITOR DESCRIPTION
The turbine speed sensor detects the transaxle input shaft speed. The ECM determines the gear shift timing based on a comparison of the turbine speed sensor (input shaft speed) with the output speed sensor (output shaft speed).
When the output shaft speed is higher than the expected value and the input shaft speed is less than 300 rpm while running with the shift lever in the D position, the ECM will conclude that there is malfunction of the transmission revolution sensor (NT). The ECM will illuminate the MIL and store the DTC.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
READ VALUE USING INTELLIGENT TESTER (SPD (NT) AND NT SENSOR VOLTAGE)
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / Data List.
In accordance with the display on the tester, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| SPD (NT) | Input turbine speed/ display: 50 rpm min.: 0 rpm max.: 12750 rpm |
Lock-up ON (After warming up engine): Input turbine speed (NT) equal to engine speed | - |
| Lock-up OFF (Idling at P or N position): Input turbine speed (NT) nearly equal to engine speed |
|||
| Vehicle stopped in R position: 0 rpm | |||
| NT Sensor Voltage | Input speed sensor output voltage/ min.: 0 V max.: 5 V |
Engine idling: Constantly changes between 0.8 to 1.6 V and 2.4 to 3.2 V |
- |
| Result | Proceed to |
|---|---|
| Data display is not within Normal Condition range | A |
| Data display is within Normal Condition range | B |
| B |
|
REPLACE ECM Click here |
| A |
|
INSPECT TRANSMISSION REVOLUTION SENSOR (NT)
Remove the transmission revolution sensor (NT) Click here and then connect the battery.
Wave a magnetic object left and right in front of the transmission revolution sensor tip (5 mm gap or closer) to change the high/low signals while measuring the current.
Note
Make sure to wave the magnetic object during the inspection. Current will not change without waving the magnetic object as indicated by the arrow in the illustration.
Measure the current according to the value(s) in the table below.
| Standard Current | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE TRANSMISSION REVOLUTION SENSOR (NT) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (TRANSMISSION REVOLUTION SENSOR (NT) - ECM)
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE ECM
Replace the ECM Click here.
| NEXT |
|
PERFORM INITIALIZATION
Perform the initialization Click here.
Check for DTCs again Click here.
| NEXT |
|
END