STOP AND START SYSTEM REGISTRATION


  1. READ NUMBER OF STARTER OPERATIONS

    Tech Tips

    If the engine stop and start ECU is being replaced, be sure to read and record the number of starter operations that is stored in the ECU before removing the ECU.

    Register this number into the new engine stop and start ECU after replacement.


    1. Connect the intelligent tester to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the tester on.

    4. Enter the following menus: Powertrain / Stop and Start / Data List / Starter Operation #.

    5. Record the value displayed by the tester.

  2. REGISTER NUMBER OF STARTER OPERATIONS

    Tech Tips

    If the engine stop and start ECU is being replaced, register the previously recorded number of starter operations into the new engine stop and start ECU.


    1. Connect the intelligent tester to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the tester on.

    4. Enter the following menus: Powertrain / Stop and Start / Utility / ECU Exchange.

    5. Following the prompts on the tester display, register the number of starter operations into the engine stop and start ECU.

  3. CLEAR NUMBER OF STARTER OPERATIONS

    Tech Tips

    After the starter assembly is replaced, be sure to clear the number of starter operations stored in the engine stop and start ECU.


    1. Connect the intelligent tester to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the tester on.

    4. Enter the following menus: Powertrain / Stop and Start / Utility / Starter Exchange.

    5. Following the prompts on the tester display, clear the number of starter operations.

  4. CLEAR A/C INFORMATION

    Tech Tips

    After the engine stop and start ECU is replaced or after an air conditioner kit is installed, clear the A/C information stored in the engine stop and start ECU.


    1. Connect the intelligent tester to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the tester on.

    4. Enter the following menus: Powertrain / Stop and Start / Utility / Reset A/C Information.

    5. Following the prompts on the tester display, clear the A/C information.

  5. REGISTER A/C INFORMATION

    A/C information is automatically registered via CAN.

    Check that the CAN communication system is functioning normally Click here.