STARTER (for 0.8 kW Type) REMOVAL


  1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

  2. SEPARATE TRANSMISSION CONTROL CABLE ASSEMBLY (for Manual Transaxle)


    1. A011BL0E01

      Remove the 2 clips <B>.

    2. Remove the 2 clips <A>, and disconnect the 2 cables from the transaxle.

  3. REMOVE STARTER ASSEMBLY


    1. A011B4H

      Open the terminal cap.

    2. Remove the nut and disconnect the terminal 30.

    3. Disconnect the connector.

    4. Remove the 2 bolts and the starter assembly.