REMOVE AIR CLEANER AND HOSE
| *1 | Clamp |
| *2 | Guide |
Loosen the clip and disconnect the ventilation hose.
Loosen the hose clamp and disconnect the air cleaner hose.
Disengage the 2 clamps and the 2 guides, and remove the air cleaner cap.
REMOVE FRONT EXHAUST PIPE ASSEMBLY
Disconnect the oxygen sensor connector and disengage the clamp.
Remove the 2 bolts and the 2 compression springs, and disconnect the front exhaust pipe assembly from the tail exhaust pipe assembly.
Remove the 2 bolts and the 2 compression springs, and the front exhaust pipe assembly from the exhaust manifold.
REMOVE MANIFOLD STAY
Remove the 2 bolts, the nut and the manifold stay.
REMOVE AIR FUEL RATIO SENSOR
Disconnect the wire harness clamp and air fuel ratio sensor connector.
Using SST, remove the air fuel ratio sensor from the exhaust manifold.
REMOVE NO. 1 EXHAUST MANIFOLD HEAT INSULATOR
Remove the 3 bolts and the No. 1 exhaust manifold heat insulator.
REMOVE EXHAUST MANIFOLD
Remove the 2 bolts, the 4 nuts and the exhaust manifold.
Remove the 2 gaskets from the cylinder head.
REMOVE NO. 1 MANIFOLD CONVERTER INSULATOR
Remove the 3 bolts and the No. 1 manifold converter insulator.