PURGE VALVE REMOVAL


  1. REMOVE DUTY VACUUM SWITCHING VALVE


    1. A0119FT

      Disconnect the duty vacuum switching valve connector.

    2. Separate the vacuum hose and the purge hose.

      Note

      Depress the duty vacuum switching valve by hand, and carefully separate the vacuum hose.

    3. A0119OH

      Remove the bolt and the duty vacuum switching valve.