DESCRIPTION
To reduce hydrocarbon (HC) emissions, fuel vapor from the fuel tank is routed through a charcoal canister to the intake manifold for combustion in the cylinders.
The ECM changes the duty signals to the purge valve (vacuum switching valve assembly) so that the intake amount of HC emissions is appropriate for the driving conditions (engine load, engine speed, vehicle speed, etc.) after the engine is warmed up.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P0443 | All of the following conditions (a) and (b) are met (1 trip detection logic):
|
|
WIRING DIAGRAM
INSPECTION PROCEDURE
Note
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Tech Tips
Read freeze frame data using the intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.
PROCEDURE
PERFORM ACTIVE TEST USING INTELLIGENT TESTER (ACTIVATE THE PURGE VSV CONTROL)
Connect the intelligent tester to the DLC3.
Disconnect the vacuum hose (charcoal canister side) from the purge valve.
Start the engine.
Turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / Active Test / Activate the VSV for Evap Control.
When the purge valve is operated using the intelligent tester, check whether the port of the purge valve applies suction to your finger.
| OK | ||||||
|---|---|---|---|---|---|---|
|
Reconnect the vacuum hose to the purge valve.
| NG |
|
INSPECT PURGE VALVE (RESISTANCE) Click here |
| OK |
|
CHECK FOR INTERMITTENT PROBLEMS Click here
INSPECT PURGE VALVE (RESISTANCE)
| *1 | Component without harness connected: (purge valve) |
Disconnect the purge valve connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Reconnect the purge valve connector.
| NG |
|
REPLACE PURGE VALVE Click here |
| OK |
|
INSPECT PURGE VALVE (POWER SOURCE VOLTAGE)
| *1 | Front view of wire harness connector: (to purge valve) |
Disconnect the purge valve connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Reconnect the purge valve connector.
| NG |
|
CHECK HARNESS AND CONNECTOR (PURGE VALVE - INTEGRATION RELAY) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (PURGE VALVE - ECM)
Disconnect the purge valve connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for Open) | ||||||
|---|---|---|---|---|---|---|
|
| Standard Resistance (Check for Short) | ||||||
|---|---|---|---|---|---|---|
|
Reconnect the purge valve connector.
Reconnect the ECM connector.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE ECM Click here
CHECK HARNESS AND CONNECTOR (PURGE VALVE - INTEGRATION RELAY)
Disconnect the purge valve connector.
Remove the integration relay.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for Open) | ||||||
|---|---|---|---|---|---|---|
|
| Standard Resistance (Check for Short) | ||||||
|---|---|---|---|---|---|---|
|
Reconnect the purge valve connector.
Reinstall the integration relay.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPAIR OR REPLACE ECM POWER SOURCE CIRCUIT Click here