MASS AIR FLOW METER INSTALLATION


  1. INSTALL MASS AIR FLOW METER


    1. A0117D6

      Install the mass air flow meter with the 2 screws.

  2. INSTALL AIR CLEANER CAP SUB-ASSEMBLY


    1. A0119FRE01

      Engage the 2 claws and 2 clamps and install the air cleaner cap.

    2. Connect the connector and 2 wire harness clamps.

      Text in Illustration
      *1 Wire harness clamp
      *2 Clamp
    3. A0118S5E01

      Connect the air cleaner hose to the air cleaner cap.

      Tech Tips


      • The clamp should contact the air cleaner hose stopper.

      • Make sure that the air cleaner hose recession is securely engaged with the air cleaner cap protrusion.