MANIFOLD ABSOLUTE PRESSURE SENSOR INSPECTION


  1. INSPECT E.F.I. VACUUM SENSOR ASSEMBLY

    A011AMAE01
    Text in Illustration
    *1

    Component without harness connected

    (E.F.I. Vacuum Sensor)


    1. Check the resistance.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        4 (THA) - 2 (E2) -20°C (-4°F) 14.6 to 17.8 kΩ
        4 (THA) - 2 (E2) 20°C (68°F) 2.21 to 2.69 kΩ
        4 (THA) - 2 (E2) 80°C (176°F) 0.29 to 0.354 kΩ

        If the result is not as specified, replace the vacuum sensor assembly.