1ND-TV COOLING SERVICE DATA

Thermostat Opening temperature 80 to 84°C (176 to 183°F)
Lift 8.5 mm (0.335 in.) at 95 °C (203°F)
Cooling fan motor 20°C (68°F) 11.2 to 14.4 A
Radiator cap sub-assembly Standard valve (for brand new cap)

94 to 122 kPa (1.0 to 1.2 kgf/cm2, 13.6 to 17.7 psi)

Minimum standard valve (after using cap)

78 kPa (0.8 kgf/cm2, 11.3 psi)

Cooling fan resistor at 20°C (68°F) 1.17 to 1.43 Ω
Cooling fan relay 3-5 10 kΩ or higher (When battery voltage is absent)
3-5 Below 1 Ω (When battery voltage applied to terminals 1 and 2)
Cooling fan relay No. 2 3-4 Below 1 Ω (When battery voltage is absent)
3-4 10 kΩ or higher (When battery voltage applied to terminals 1 and 2)
3-5 10 kΩ or higher (When battery voltage is absent)
3-5 Below 1 Ω (When battery voltage applied to terminals 1 and 2)