BACK DOOR OPENER SWITCH INSPECTION


  1. INSPECT BACK DOOR OUTSIDE HANDLE SUB-ASSEMBLY (w/o Entry and Start System)


    1. A0119JU

      Check the door opener switch.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        1 - 2 Switch released 10 kΩ or higher
        1 - 2 Switch pressed in Below 1 Ω

        If the result is not as specified, replace the back door outside handle.

  2. INSPECT BACK DOOR OUTSIDE HANDLE SUB-ASSEMBLY (w/ Entry and Start System)


    1. A0119NH

      Check the door opener switch.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        1 - 2 Switch released 10 kΩ or higher
        1 - 2 Switch pressed in Below 1 Ω

        If the result is not as specified, replace the back door outside handle.

    2. A011A7D

      Check the lock switch.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        3 - 4 Switch released 10 kΩ or higher
        3 - 4 Switch pressed in Below 1 Ω

        If the result is not as specified, replace the back door outside handle.