RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
Start up the engine.
Switch the A/C on.
Turn the blower switch to on.
Operate the cooler compressor with an engine speed of approximately 1000 rpm for 5 to 6 minutes to circulate the refrigerant and collect the remaining compressor oil from each component, in the cooler compressor.
Stop the engine.
Remove the caps from the service valves on the refrigerant line.
| *a | Engine room side |
| *b | Wheel house side |
| Engine Type | RHD | LHD |
|---|---|---|
| 1KR-FE | Engine room | Engine room |
| 1NR-FE | Engine room | Engine room |
| 1ND-TV | Engine room | Engine room |
| Engine Type | RHD | LHD |
|---|---|---|
| 1KR-FE | Wheel house | Wheel house |
| 1NR-FE | Wheel house | Wheel house |
| 1ND-TV | Wheel house | Wheel house |
Connect the refrigerant recovery unit.
Recover the refrigerant from the air conditioning system using a refrigerant recovery unit.
Tech Tips
Use the refrigerant recovery unit in accordance with the manufacturer's instruction manual.
REMOVE AIR CONDITIONER PRESSURE SENSOR
Disconnect the connector.
Using a deep socket wrench 27 mm, remove the pressure sensor.
Note