AIR CONDITIONING PRESSURE SENSOR REMOVAL


  1. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM


    1. Start up the engine.

    2. Switch the A/C on.

    3. Turn the blower switch to on.

    4. Operate the cooler compressor with an engine speed of approximately 1000 rpm for 5 to 6 minutes to circulate the refrigerant and collect the remaining compressor oil from each component, in the cooler compressor.

    5. Stop the engine.

    6. Remove the caps from the service valves on the refrigerant line.

      A011ADWE02
      Text in illustration
      *a Engine room side
      *b Wheel house side
      Access to Hi Pressure Side
      Engine Type RHD LHD
      1KR-FE Engine room Engine room
      1NR-FE Engine room Engine room
      1ND-TV Engine room Engine room
      Access to Low Pressure Side
      Engine Type RHD LHD
      1KR-FE Wheel house Wheel house
      1NR-FE Wheel house Wheel house
      1ND-TV Wheel house Wheel house
    7. Connect the refrigerant recovery unit.

    8. Recover the refrigerant from the air conditioning system using a refrigerant recovery unit.

      Tech Tips

      Use the refrigerant recovery unit in accordance with the manufacturer's instruction manual.

  2. REMOVE AIR CONDITIONER PRESSURE SENSOR

    A0116Y6

    1. Disconnect the connector.

    2. Using a deep socket wrench 27 mm, remove the pressure sensor.

      Note