LUMBAR SWITCH (for Manual Seat) INSPECTION


  1. INSPECT LUMBAR FRONT POWER SEAT SWITCH (for LHD)


    1. A003CPSE01
      Text in Illustration
      *1 Hold
      *2 Release
      *3

      Component without harness connected

      (Lumbar Front Power Seat Switch)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      3 (B) - 4 (H) Hold Below 1 Ω
      3 (B) - 4 (H) Off 10 kΩ or higher
      1 (R) - 3 (B)
      1 (R) - 3 (B) Release Below 1 Ω

      If the result is not as specified, replace the lumbar front power seat switch.

  2. INSPECT LUMBAR FRONT POWER SEAT SWITCH (for RHD)


    1. A003D8BE01
      Text in Illustration
      *1 Release
      *2 Hold
      *3

      Component without harness connected

      (Lumbar Front Power Seat Switch)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      3 (B) - 4 (H) Hold Below 1 Ω
      3 (B) - 4 (H) Off 10 kΩ or higher
      1 (R) - 3 (B)
      1 (R) - 3 (B) Release Below 1 Ω

      If the result is not as specified, replace the lumbar front power seat switch.