CHECK POSITION CONTROL ECU (for LHD)
Disconnect the O26 and O27 ECU connectors.
Measure the resistance and voltage according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| O26-1 (SYSB) - Body ground | R - Body ground | System power source | Always | 11 to 14 V |
| O26-21 (GND2) - Body ground | BR - Body ground | Ground | Always | Below 1 Ω |
| O27-1 (GND) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
| O27-5 (+B) - Body ground | L - Body ground | Power source | Always | 11 to 14 V |
If the result is not as specified, there may be a malfunction on the wire harness side.
Reconnect the O26 and O27 ECU connectors.
Measure the voltage according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| O26-3 (PVCC) - O27-1 (GND) | GR - W-B | Reclining position sensor power supply | Power seat operation | 5.5 to 6.5 V |
| O26-5 (SSRR) - O27-1 (GND) | P - W-B | Reclining position signal | Reclining operation | 0 to 6.5 V |
| O26-6 (SSRS) - O27-1 (GND) | LG - W-B | Sliding position signal | Sliding operation | 0 to 6.5 V |
| O26-7 (SSFV) - O27-1 (GND) | B - W-B | Front vertical position signal | Front vertical operation | 0 to 6.5 V |
| O26-8 (SSRL) - O27-1 (GND) | GR - W-B | Lifter position signal | Lifter operation | 0 to 6.5 V |
| O26-9 (SLDF) - O27-1 (GND) | SB - W-B | Power seat switch signal | Sliding switch (forward) off | 11 to 14 V |
| Sliding switch (forward) on | Below 1 V | |||
| O26-10 (SLDR) - O27-1 (GND) | LG - W-B | Power seat switch signal | Sliding switch (rearward) off | 11 to 14 V |
| Sliding switch (rearward) on | Below 1 V | |||
| O26-11 (RCLF) - O27-1 (GND) | G - W-B | Power seat switch signal | Reclining switch (forward) off | 11 to 14 V |
| Reclining switch (forward) on | Below 1 V | |||
| O26-12 (RCLR) - O27-1 (GND) | GR - W-B | Power seat switch signal | Reclining switch (rearward) off | 11 to 14 V |
| Reclining switch (rearward) on | Below 1 V | |||
| O26-13 (FUP) - O27-1 (GND) | R - W-B | Power seat switch signal | Front vertical switch (upward) off | 11 to 14 V |
| Front vertical switch (upward) on | Below 1 V | |||
| O26-14 (FDWN) - O27-1 (GND) | L - W-B | Power seat switch signal | Front vertical switch (downward) off | 11 to 14 V |
| Front vertical switch (downward) on | Below 1 V | |||
| O26-15 (LUP) - O27-1 (GND) | W - W-B | Power seat switch signal | Lifter switch (upward) off | 11 to 14 V |
| Lifter switch (upward) on | Below 1 V | |||
| O26-16 (LDWN) - O27-1 (GND) | V - W-B | Power seat switch signal | Lifter switch (downward) off | 11 to 14 V |
| Lifter switch (downward) on | Below 1 V | |||
| O26-23 (PVCC) - O27-1 (GND) | W - W-B | Sliding position sensor power supply | Power seat operation | 5.5 to 6.5 V |
| O26-24 (PVCC) - O27-1 (GND) | L - W-B | Front vertical position sensor power supply | Power seat operation | 5.5 to 6.5 V |
| O26-25 (PVCC) - O27-1 (GND) | V - W-B | Lifter position sensor power supply | Power seat operation | 5.5 to 6.5 V |
| O27-2 (SLD+) - O27-1 (GND) | B - W-B | Slide motor signal (forward) | Seat moving forward using sliding switch | 11 to 14 V |
| Other | Below 1 V | |||
| O27-3 (SLD-) - O27-1 (GND) | P - W-B | Slide motor signal (rearward) | Seat moving rearward using sliding switch | 11 to 14 V |
| Other | Below 1 V | |||
| O27-4 (FRV-) - O27-1 (GND) | G - W-B | Front vertical motor signal (downward) | Seat cushion front portion lowering using front vertical switch | 11 to 14 V |
| Other | Below 1 V | |||
| O27-6 (FRV+) - O27-1 (GND) | R - W-B | Front vertical motor signal (upward) | Seat cushion front portion rising using front vertical switch | 11 to 14 V |
| Other | Below 1 V | |||
| O27-7 (LFT+) - O27-1 (GND) | SB - W-B | Lifter motor signal (upward) | Seat rising using lifter switch | 11 to 14 V |
| Other | Below 1 V | |||
| O27-8 (RCL+) - O27-1 (GND) | LG - W-B | Reclining motor signal (forward) | Seatback moving forward using reclining switch | 11 to 14 V |
| Other | Below 1 V | |||
| O27-9 (LFT-) - O27-1 (GND) | W - W-B | Lifter motor signal (downward) | Seat lowering using lifter switch | 11 to 14 V |
| Other | Below 1 V | |||
| O27-10 (RCL-) - O27-1 (GND) | V - W-B | Reclining motor signal (rearward) | Seatback moving rearward using reclining switch | 11 to 14 V |
| Other | Below 1 V |
If the result is not as specified, the ECU may have a malfunction.
CHECK POSITION CONTROL ECU (for RHD)
Disconnect the O16 and O17 ECU connectors.
Measure the resistance and voltage according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| O16-1 (SYSB) - Body ground | R - Body ground | System power source | Always | 11 to 14 V |
| O16-21 (GND2) - Body ground | BR - Body ground | Ground | Always | Below 1 Ω |
| O17-1 (GND) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
| O17-5 (+B) - Body ground | L - Body ground | Power source | Always | 11 to 14 V |
If the result is not as specified, there may be a malfunction on the wire harness side.
Reconnect the O16 and O17 ECU connectors.
Measure the voltage according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| O16-3 (PVCC) - O17-1 (GND) | GR - W-B | Reclining position sensor power supply | Power seat operation | 5.5 to 6.5 V |
| O16-5 (SSRR) - O17-1 (GND) | P - W-B | Reclining position signal | Reclining operation | 0 to 6.5 V |
| O16-6 (SSRS) - O17-1 (GND) | LG - W-B | Sliding position signal | Sliding operation | 0 to 6.5 V |
| O16-7 (SSFV) - O17-1 (GND) | B - W-B | Front vertical position signal | Front vertical operation | 0 to 6.5 V |
| O16-8 (SSRL) - O17-1 (GND) | GR - W-B | Lifter position signal | Lifter operation | 0 to 6.5 V |
| O16-9 (SLDF) - O17-1 (GND) | SB - W-B | Power seat switch signal | Sliding switch (forward) off | 11 to 14 V |
| Sliding switch (forward) on | Below 1 V | |||
| O16-10 (SLDR) - O17-1 (GND) | LG - W-B | Power seat switch signal | Sliding switch (rearward) off | 11 to 14 V |
| Sliding switch (rearward) on | Below 1 V | |||
| O16-11 (RCLF) - O17-1 (GND) | G - W-B | Power seat switch signal | Reclining switch (forward) off | 11 to 14 V |
| Reclining switch (forward) on | Below 1 V | |||
| O16-12 (RCLR) - O17-1 (GND) | GR - W-B | Power seat switch signal | Reclining switch (rearward) off | 11 to 14 V |
| Reclining switch (rearward) on | Below 1 V | |||
| O16-13 (FUP) - O17-1 (GND) | R - W-B | Power seat switch signal | Front vertical switch (upward) off | 11 to 14 V |
| Front vertical switch (upward) on | Below 1 V | |||
| O16-14 (FDWN) - O17-1 (GND) | L - W-B | Power seat switch signal | Front vertical switch (downward) off | 11 to 14 V |
| Front vertical switch (downward) on | Below 1 V | |||
| O16-15 (LUP) - O17-1 (GND) | W - W-B | Power seat switch signal | Lifter switch (upward) off | 11 to 14 V |
| Lifter switch (upward) on | Below 1 V | |||
| O16-16 (LDWN) - O17-1 (GND) | V - W-B | Power seat switch signal | Lifter switch (downward) off | 11 to 14 V |
| Lifter switch (downward) on | Below 1 V | |||
| O16-23 (PVCC) - O17-1 (GND) | W - W-B | Sliding position sensor power supply | Power seat operation | 5.5 to 6.5 V |
| O16-24 (PVCC) - O17-1 (GND) | L - W-B | Front vertical position sensor power supply | Power seat operation | 5.5 to 6.5 V |
| O16-25 (PVCC) - O17-1 (GND) | V - W-B | Lifter position sensor power supply | Power seat operation | 5.5 to 6.5 V |
| O17-2 (SLD+) - O17-1 (GND) | B - W-B | Slide motor signal (forward) | Seat moving forward using sliding switch | 11 to 14 V |
| Other | Below 1 V | |||
| O17-3 (SLD-) - O17-1 (GND) | P - W-B | Slide motor signal (rearward) | Seat moving rearward using sliding switch | 11 to 14 V |
| Other | Below 1 V | |||
| O17-4 (FRV-) - O17-1 (GND) | G - W-B | Front vertical motor signal (downward) | Seat cushion front portion lowering using front vertical switch | 11 to 14 V |
| Other | Below 1 V | |||
| O17-6 (FRV+) - O17-1 (GND) | R - W-B | Front vertical motor signal (upward) | Seat cushion front portion rising using front vertical switch | 11 to 14 V |
| Other | Below 1 V | |||
| O17-7 (LFT+) - O17-1 (GND) | SB - W-B | Lifter motor signal (upward) | Seat rising using lifter switch | 11 to 14 V |
| Other | Below 1 V | |||
| O17-8 (RCL+) - O17-1 (GND) | LG - W-B | Reclining motor signal (forward) | Seatback moving forward using reclining switch | 11 to 14 V |
| Other | Below 1 V | |||
| O17-9 (LFT-) - O17-1 (GND) | W - W-B | Lifter motor signal (downward) | Seat lowering using lifter switch | 11 to 14 V |
| Other | Below 1 V | |||
| O17-10 (RCL-) - O17-1 (GND) | V - W-B | Reclining motor signal (rearward) | Seatback moving rearward using reclining switch | 11 to 14 V |
| Other | Below 1 V |
If the result is not as specified, the ECU may have a malfunction.