DESCRIPTION
The blower with fan motor sub-assembly is operated by signals from the air conditioning amplifier assembly. The blower with fan motor sub-assembly speed signals are transmitted by changes in the duty ratio.
Duty Ratio:
The duty ratio is the ratio of the blower with fan motor sub-assembly ON time (T1) to the total of the blower with fan motor sub-assembly ON and OFF time (T2).
The air conditioning amplifier assembly controls the blower with fan motor sub-assembly speed.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
PERFORM ACTIVE TEST USING INTELLIGENT TESTER
Select the Active Test, use the intelligent tester to generate a control command, and then check that the blower with fan motor sub-assembly operates.
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Blower Motor | Blower motor speed level | Min.: 0, Max.: 31 | - |
| OK |
|---|
| Blower motor operates and blower motor speed changes. |
| Result | Proceed to |
|---|---|
| OK (Blower motor operates normally) | A |
| NG (Blower motor does not operate) | B |
| NG (Blower motor operates but does not change speed) | C |
| B |
|
CHECK HARNESS AND CONNECTOR (BLOWER MOTOR - BATTERY AND BODY GROUND) Click here |
| C |
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - BODY GROUND) Click here |
| A |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here
CHECK HARNESS AND CONNECTOR (BLOWER MOTOR - BATTERY AND BODY GROUND)
| *1 | Front view of wire harness connector (to Blower with Fan Motor Sub-assembly) |
Disconnect the D29 motor connector.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK HARNESS AND CONNECTOR (BLOWER MOTOR - AIR CONDITIONING AMPLIFIER)
| *1 | Front view of wire harness connector (to Blower with Fan Motor Sub-assembly) |
| *2 | Rear view of wire harness connector (to Air Conditioning Amplifier Assembly) |
Disconnect the D47 amplifier connector.
Disconnect the D29 motor connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK BLOWER WITH FAN MOTOR SUB-ASSEMBLY (OPERATION)
Replace the blower with fan motor sub-assembly with a new or normally functioning one Click here.
Operate the blower with fan motor sub-assembly to check that it functions properly.
| OK |
|---|
| Blower with fan motor sub-assembly operates normally. |
| NG |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Click here |
| OK |
|
END (BLOWER WITH FAN MOTOR SUB-ASSEMBLY IS FAULTY)
CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - BODY GROUND)
| *1 | Rear view of wire harness connector (to Air Conditioning Amplifier Assembly) |
Disconnect the D47 amplifier connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (BLW SIGNAL)
| *1 | Component with harness connected (Air Conditioning Amplifier Assembly) |
Remove the air conditioning amplifier assembly with its connectors still connected Click here.
Using an oscilloscope, check the waveform.
| Item | Content |
|---|---|
| Terminal No. (Symbol) | D47-23 (BLW) - D47-14 (GND) |
| Tool Setting | 1 V/DIV., 500 μs/DIV. |
| Condition | Ignition switch ON Blower switch lo |
| OK |
|---|
| Waveform is as shown in the illustration. |
Tech Tips
Waveform varies with the blower level.
| NG |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Click here |
| OK |
|
CHECK BLOWER WITH FAN MOTOR SUB-ASSEMBLY (OPERATION)
Replace the blower with fan motor sub-assembly with a new or normally functioning one Click here.
Operate the blower with fan motor sub-assembly to check that it functions properly.
| OK |
|---|
| Blower with fan motor sub-assembly operates normally. |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
END (BLOWER WITH FAN MOTOR SUB-ASSEMBLY IS FAULTY)