OCCUPANT DETECTION SENSOR INSPECTION


  1. INSPECT SEAT CUSHION COVER WITH PAD

    A00DSL6E01

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 3 More than 147 N (15 kgf, 33.0 lbf) applied to occupant detection sensor Below 100 Ω

      If the result is not as specified, replace the seat cushion cover with pad.