VACUUM REGULATING VALVE INSPECTION


  1. INSPECT VACUUM REGULATING VALVE ASSEMBLY


    1. A003AX0E01
      Text in Illustration
      *1

      Component without harness connected

      (Vacuum Regulating Valve)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 11.1 to 12.5 Ω

      If the result is not as specified, replace the vacuum regulating valve assembly.

    2. Inspect vacuum regulating valve operation.


      1. A003EB3E01

        Check that air flows from port E to G.

      2. A003BG0E01

        Apply battery voltage to the terminals as shown in the illustration.

      3. Check that air flows from port E to the filter.

        If the result is not as specified, replace the vacuum regulating valve assembly.