| DTC Code | DTC Name |
|---|---|
| P2759 | Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU) |
DESCRIPTION
The amount of current flow to the solenoid is controlled by the duty ratio* of the TCM output signal. The higher the duty ratio becomes, the higher the lock-up hydraulic pressure becomes during the lock-up operation.
Tech Tips
*: The duty ratio is the ratio of the electrical current on time (A) to the total of the electrical current on and off time (A + B).
Duty Ratio (%) = (A / (A + B)) x 100
| DTC Code | DTC Detection Condition | Trouble Area |
|---|---|---|
| P2759 | Open or short is detected in shift solenoid valve SLU circuit for 1 second or more while driving (1-trip detection logic). |
|
MONITOR DESCRIPTION
When an open or short in the shift solenoid valve SLU circuit is detected, the TCM determines there is a malfunction. The TCM will turn on the MIL and store the DTC.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLU)
| *1 | Component without TCM connected (Transmission Wire) |
Remove the TCM.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
| OK |
|
REPLACE TCM Click here
INSPECT SHIFT SOLENOID VALVE SLU
| *1 | Component without harness connected (Shift Solenoid Valve SLU) |
Remove shift solenoid valve SLU.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| OK | ||||
|---|---|---|---|---|
|
| NG |
|
REPLACE SHIFT SOLENOID VALVE SLU Click here |
| OK |
|
REPLACE TRANSMISSION WIRE Click here