СИСТЕМА SFI, Diagnostic DTC:P0110, P0112, P0113

DTC Code DTC Name
P0110 Intake Air Temperature Circuit Malfunction
P0112 Intake Air Temperature Circuit Low Input
P0113 Intake Air Temperature Circuit High Input

DESCRIPTION

A005TXAE02
DTC No. DTC Detection Condition Trouble Area
P0110 An open or short in the IAT sensor circuit for 0.5 seconds (1 trip detection logic).
  • Open or short in IAT sensor circuit

  • IAT sensor (built into MAF meter)

  • ECM

P0112 A short in the IAT sensor circuit for 0.5 seconds (1 trip detection logic).
  • Short in IAT sensor circuit

  • IAT sensor (built into MAF meter)

  • ECM

P0113 An open in the IAT sensor circuit for 0.5 seconds (1 trip detection logic).
  • Open in IAT sensor circuit

  • IAT sensor (built into MAF meter)

  • ECM

Tech Tips

When any of these DTCs are stored, check the IAT using the intelligent tester. Enter the following menus: Powertrain / Engine and ECT / Data List / Intake Air.

Temperature Displayed Malfunction
-40°C (-40°F) Open circuit
140°C (284°F) or higher Short circuit

WIRING DIAGRAM

A005W3ZE01

INSPECTION PROCEDURE

Tech Tips

Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.

PROCEDURE

  1. READ VALUE USING INTELLIGENT TESTER (INTAKE AIR TEMPERATURE)

    1. Connect the intelligent tester to the DLC3.

    2. Turn the engine switch on (IG) and turn the tester on.

    3. Enter the following menus: Powertrain / Engine and ECT / Data List / Intake Air.

    4. Read the value displayed on the tester.

      Standard
      Same as actual Intake Air Temperature (IAT).
      Result
      Result Proceed to
      -40°C (-40°F) A
      140°C (284°F) or higher B
      Same as actual IAT C

      Tech Tips

      • If there is an open circuit, the intelligent tester indicates -40°C (-40°F).

      • If there is a short circuit, the intelligent tester indicates 140°C (284°F) or higher.

    B
    C
    A
  2. READ VALUE USING INTELLIGENT TESTER (CHECK FOR OPEN IN WIRE HARNESS)

    A005W2EE03
    1. Disconnect the B2 Mass Air Flow (MAF) meter connector.

    2. Connect terminals THA and E2 of the MAF meter wire harness connector.

    3. Connect the intelligent tester to the DLC3.

    4. Turn the engine switch on (IG) and turn the tester on.

    5. Enter the following menus: Powertrain / Engine and ECT / Data List / Intake Air.

    6. Read the value displayed on the tester.

      Standard value
      140°C (284°F) or higher
      Text in Illustration
      *1 MAF Meter
      *2 ECM
      *3

      Front view of wire harness connector

      (to MAF Meter)

    7. Reconnect the MAF meter connector.

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM)

    1. Disconnect the B2 MAF meter connector.

      A005RGGE02
    2. Disconnect the B39 ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      B2-1 (THA) - B39-65 (THA) Always Below 1 Ω
      B2-2 (E2) - B39-88 (ETHA)
      Text in Illustration
      *1

      Front view of wire harness connector

      (to MAF Meter)

      *2

      Front view of wire harness connector

      (to ECM)

    4. Reconnect the MAF meter connector.

    5. Reconnect the ECM connector.

    NG
    OK
  4. READ VALUE USING INTELLIGENT TESTER (CHECK FOR SHORT IN WIRE HARNESS)

    A005R53E03
    1. Disconnect the B2 MAF meter connector.

    2. Connect the intelligent tester to the DLC3.

    3. Turn the engine switch on (IG) and turn the tester on.

    4. Enter the following menus: Powertrain / Engine and ECT / Data List / Intake Air.

    5. Read the value displayed on the tester.

      Standard value
      -40°C (-40°F)
      Text in Illustration
      *1 MAF Meter
      *2 ECM
    6. Reconnect the MAF meter connector.

    NG
    OK
  5. CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM)

    A005RGGE07
    1. Disconnect the B2 MAF meter connector.

    2. Disconnect the B39 ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      B2-1 (THA) or B39-65 (THA) - Body ground Always 10 kΩ or higher
      Text in Illustration
      *1

      Front view of wire harness connector

      (to MAF Meter)

      *2

      Front view of wire harness connector

      (to ECM)

    4. Reconnect the MAF meter connector.

    5. Reconnect the ECM connector.

    NG
    OK