КОРПУС КЛАПАНОВ В СБОРЕ ПРОВЕРКА

  1. INSPECT SHIFT SOLENOID VALVE SLT

    A005V5JE01
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
      Text in Illustration
      *1

      Component without harness connected

      (Shift Solenoid Valve SLT)

    2. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition
      • Battery positive (+) with a 21 W bulb → Terminal 1

      • Battery negative (-) → Terminal 2

      Valve moves and makes an operating noise

      If the result is not as specified, replace the solenoid valve.

  2. INSPECT SHIFT SOLENOID VALVE SL1

    A005V5JE01
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
      Text in Illustration
      *1

      Component without harness connected

      (Shift Solenoid Valve SL1)

    2. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition
      • Battery positive (+) with a 21 W bulb → Terminal 1

      • Battery negative (-) → Terminal 2

      Valve moves and makes an operating noise

      If the result is not as specified, replace the solenoid valve.

  3. INSPECT SHIFT SOLENOID VALVE DSL

    A005SVCE01
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Shift solenoid valve DSL connector terminal - Shift solenoid valve DSL body 20°C (68°F) 11 to 13 Ω
      Text in Illustration
      *1

      Component without harness connected

      (Shift Solenoid Valve DSL)

    2. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition
      • Battery positive (+) → Shift solenoid valve DSL connector

      • Battery negative (-) → Shift solenoid valve DSL body

      Valve moves and makes an operating noise

      If the result is not as specified, replace the solenoid valve.

  4. INSPECT SHIFT SOLENOID VALVE SL2

    A005V5JE01
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
      Text in Illustration
      *1

      Component without harness connected

      (Shift Solenoid Valve SL2)

    2. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition
      • Battery positive (+) with a 21 W bulb → Terminal 1

      • Battery negative (-) → Terminal 2

      Valve moves and makes an operating noise

      If the result is not as specified, replace the solenoid valve.

  5. INSPECT SHIFT SOLENOID VALVE S4

    A005SVCE01
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Shift solenoid valve DSL connector terminal - Shift solenoid valve DSL body 20°C (68°F) 11 to 13 Ω
      Text in Illustration
      *1

      Component without harness connected

      (Shift Solenoid Valve S4)

    2. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

      OK
      Measurement Condition Specified Condition
      • Battery positive (+) → Shift solenoid valve DSL connector

      • Battery negative (-) → Shift solenoid valve DSL body

      Valve moves and makes an operating noise

      If the result is not as specified, replace the solenoid valve.