PROCEDURE
INSPECT HEATER WATER PUMP ASSEMBLY
| *a | Component without harness connected (Heater Water Pump Assembly) |
Connect a positive (+) lead from the battery to terminal 2 (+B) and a negative (-) lead to terminal 1 (-).
| OK |
|---|
| The heater water pump assembly operates smoothly. |
Note
Perform this test within 10 seconds to prevent the coil from burning out.