DATA LIST
Tech Tips
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
Note
In the table below, the values listed under Normal Condition are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Warm up the engine.
Turn the engine switch off.
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Engine / Data List.
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Battery Voltage | Battery voltage | Min.: 0.0 V Max.: 65.5 V |
11 to 14 V (Idling) | If the result is not as specified, abnormal battery voltage is suspected. |
| Battery Current | Battery current | Min.: -125.0 A Max.: 124.9 A |
Changes according to generator output (While driving after engine warmed up) |
|
| Battery Temperature | Battery fluid temperature | Min.: -40.0°C (-40°F) Max.: 6513.5 °C (11756 °F) |
Changes according to actual temperature (While driving after engine warmed up) |
|
| Alternator Output Duty Ratio | LIN terminal output (charging control signal) | Min.: 0.0% Max.: 399.9% |
Changes in accordance with the generator output (During charging control) |
If the result is not as specified, a malfunction of the charging control system is suspected. |
| Alternator Voltage - Non Active Test | Requested voltage when regulator forced drive is not executed | Min.: 0.000 V Max.: 79.998 V |
12.5 to 14.8 V (After engine start (Varies with regulator temperature or driving conditions)) |
Active Test support data |
| Voltage of Alternator | Requested voltage when regulator forced drive is executed | Min.: 0.0 V Max.: 79.9 V |
Required instruction voltage value when the Active Test "Control the Voltage of Alternator" is executed (12.5 to 14.7 V): After engine started | Malfunction of the charging control system can be the cause of malfunction |
| Previous Trip Alternator Max Output Time | Generator maximum generating time during previous drive | Min.: 0 sec. Max.: 65535 sec. |
- | w/ Stop and Start System |
| Initial Engine Battery Minimum Voltage | Minimum battery voltage at engine start | Min.: 0.0 V Max.: 25.5 V |
- | w/ Stop and Start System |
| Previous Trip Charge Control Time | Charging control time during previous drive | Min.: 0 sec. Max.: 65535 sec. |
- | w/ Stop and Start System |
| Previous Trip Average Battery Temperature | Battery average temperature during previous drive | Min.: -40°C (-40°F) Max.: 215°C (419°F) |
- | w/ Stop and Start System |
Tech Tips
Normal Condition: If no idling conditions are specified, the shift lever should be in N or P, and the A/C switch and all accessory switches should be off.
ACTIVE TEST
Tech Tips
Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Engine / Active Test.
According to the display on the GTS, perform the Active Test.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Control the Voltage of Alternator | Requested output voltage of generator regulator during forced activation | Between 12.5 and 14.7 V | Test is possible after engine start |