AUTOMATIC TRANSMISSION SYSTEM(for 2GR-FKS) Transmission Control Switch Circuit

DESCRIPTION

The transmission control switch detects when the shift lever is moved to M.

Using the transmission control switch, when the shift lever is in M, it is possible to select between 1st and 8th gears (M1 to M8).

Moving the shift lever to "+" once selects the next higher gear, and moving the shift lever to "-" once selects the next lower gear.

WIRING DIAGRAM

B0072ZKE99

CAUTION / NOTICE / HINT

Note

Inspect the fuses for circuits related to this system before performing the following procedure.

PROCEDURE


  1. INSPECT TRANSMISSION CONTROL SWITCH (TRANSMISSION FLOOR SHIFT ASSEMBLY)


    1. Disconnect the O77 transmission control switch (transmission floor shift assembly) connector.

    2. B0076PWC48
      *a

      Component without harness connected

      (Transmission Control Switch (Transmission Floor Shift Assembly))

      for LHD:

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      4 (IG) - 5 (S) Shift lever in M, "+" and "-" Below 1 Ω
      Shift lever not in M, "+" and "-" 10 kΩ or higher
      3 (SFTU) - 2 (E) Shift lever held in "+" (Up-shift) Below 1 Ω
      Shift lever in M 10 kΩ or higher
      1 (SFTD) - 2 (E) Shift lever held in "-" (Down-shift) Below 1 Ω
      Shift lever in M 10 kΩ or higher
    3. B0076PWC22
      *a

      Component without harness connected

      (Transmission Control Switch (Transmission Floor Shift Assembly))

      for RHD:

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      4 (IG) - 5 (S) Shift lever in M, "+" and "-" Below 1 Ω
      Shift lever not in M, "+" and "-" 10 kΩ or higher
      1 (SFTU) - 2 (E) Shift lever held in "+" (Up-shift) Below 1 Ω
      Shift lever in M 10 kΩ or higher
      3 (SFTD) - 2 (E) Shift lever held in "-" (Down-shift) Below 1 Ω
      Shift lever in M 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (TRANSMISSION CONTROL SWITCH - BATTERY, BODY GROUND)


    1. Turn the engine switch on (IG).

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      O77-4 (IG) - Body ground Engine switch on (IG) 11 to 14 V
      Engine switch off Below 1 V
    3. Turn the engine switch off.

    4. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      O77-2 (E) - Body ground Always Below 1 Ω
      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (TRANSMISSION CONTROL SWITCH - ECM)


    1. Connect the O77 transmission control switch (transmission floor shift assembly) connector.

    2. Disconnect the A96 ECM connector.

    3. Turn the engine switch on (IG).

    4. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      A96-17 (S) - Body ground Shift lever in M, "+" and "-" 11 to 14 V
      Shift lever not in M, "+" and "-" Below 1 V
    5. Turn the engine switch off.

    6. Disconnect the spiral cable sub-assembly connector.

    7. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A96-38 (SFTU) - Body ground Shift lever held in "+" (Up-shift) Below 1 Ω
      Shift lever in M 10 kΩ or higher
      A96-37 (SFTD) - Body ground Shift lever held in "-" (Down-shift) Below 1 Ω
      Shift lever in M 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    OK
    NG