STARTER INSTALLATION

PROCEDURE


  1. INSTALL STARTER ASSEMBLY


    1. Install the starter assembly with the 2 bolts.

      Torque:
      58 N*m  { 591 kgf*cm, 43 ft.*lbf }
    2. Connect terminal 30 with the nut.

      Torque:
      9.8 N*m  { 100 kgf*cm, 87 in.*lbf }
    3. Close the terminal cap.

    4. Connect the starter assembly connector.

  2. INSTALL EXHAUST MANIFOLD SUB-ASSEMBLY LH(TWC: Front Catalyst)

    Click here

  3. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click here