CANISTER(w/ Canister Pump Module) REMOVAL

PROCEDURE


  1. REMOVE NO. 1 FLOOR UNDER COVER ASSEMBLY


    1. B0073DR

      Disconnect the 5 grommets and remove the 4 clips and No. 1 floor under cover assembly.

  2. REMOVE CANISTER (CHARCOAL CANISTER ASSEMBLY)


    1. B0073FW

      Disengage the 4 wire harness clamps from the canister (charcoal canister assembly).

    2. B0074NE

      Disconnect the leak detection pump sub-assembly connector.

    3. Disconnect the vent line hose from the canister (charcoal canister assembly).

      B0073ZIC01
      *1 Vent Line Hose *2 Pipe (Canister (Charcoal Canister Assembly))
      *a Pinch *b Pull
      *c Retainer *d Tab
      *e Tube Connector *f O-Ring

      Note


      • Remove any dirt or foreign matter on the tube connector before performing this work.

      • Do not allow any scratches or foreign matter to get on the parts when disconnecting them as the tube connector has an O-ring that seals the pipe (canister (charcoal canister assembly)).

      • Perform this work by hand. Do not use any tools.

      • Do not forcibly bend, twist or turn the vent line hose.

      • Protect the disconnected parts by covering them with plastic bags after disconnecting the vent line hose.

      • If the tube connector and pipe (canister (charcoal canister assembly)) are stuck, push and pull to release them.

      Tech Tips

      Do not remove the retainer.


      1. Pinch the tabs of the retainer to disengage the lock claws and pull the retainer out as shown in the illustration.

      2. Pull off the vent line hose.

    4. B00764T

      Slide the 2 clips and remove the purge line hose from the canister (charcoal canister assembly).

    5. Disconnect the air line tube from the canister (charcoal canister assembly).

      B0077SEC01
      *1 Air Line Tube *2 Pipe (Canister (Charcoal Canister Assembly))
      *a Pinch *b Pull
      *c Retainer *d Tab
      *e Tube Connector *f O-Ring

      Note


      • Remove any dirt or foreign matter on the tube connector before performing this work.

      • Do not allow any scratches or foreign matter to get on the parts when disconnecting them as the tube connector has an O-ring that seals the pipe (canister (charcoal canister assembly)).

      • Perform this work by hand. Do not use any tools.

      • Do not forcibly bend, twist or turn the air line tube.

      • Protect the disconnected parts by covering them with plastic bags after disconnecting the air line tube.

      • If the tube connector and pipe (canister (charcoal canister assembly)) are stuck, push and pull to release them.

      Tech Tips

      Do not remove the retainer.


      1. Pinch the tabs of the retainer to disengage the lock claws and pull the retainer out as shown in the illustration.

      2. Pull off the air line tube.

    6. B0072PK

      Remove the 3 nuts.

    7. Disengage the clip from the vehicle body to remove the canister (charcoal canister assembly).

  3. REMOVE LEAK DETECTION PUMP SUB-ASSEMBLY


    1. Before removing the leak detection pump sub-assembly, clean the charcoal canister sub-assembly by blowing air into it to ensure that the charcoal canister sub-assembly is free of foreign matter.

      Note


      • Make sure to clean the charcoal canister sub-assembly using air only.

      • Do not use gasoline, thinners or solvents.

    2. Disconnect the charcoal canister outlet tube sub-assembly from the leak detection pump sub-assembly.

      B007631C01
      *1 Charcoal Canister Outlet Tube Sub-assembly *2 Pipe (Leak Detection Pump Sub-assembly)
      *a Pinch *b Pull
      *c Retainer *d Tab
      *e Tube Connector *f O-Ring

      Note


      • Remove any dirt or foreign matter on the tube connector before performing this work.

      • Do not allow any scratches or foreign matter to get on the parts when disconnecting them as the tube connector has an O-ring that seals the pipe (leak detection pump sub-assembly).

      • Perform this work by hand. Do not use any tools.

      • Do not forcibly bend, twist or turn the charcoal canister outlet tube sub-assembly.

      • Protect the disconnected parts by covering them with plastic bags after disconnecting the charcoal canister outlet tube sub-assembly.

      • If the tube connector and pipe (leak detection pump sub-assembly) are stuck, push and pull to release them.

      Tech Tips

      Do not remove the retainer.


      1. Pinch the tabs of the retainer to disengage the lock claws and pull the retainer out as shown in the illustration.

      2. Pull off the charcoal canister outlet tube sub-assembly.

    3. B0076QMC01
      *a Protective Tape

      While disengaging the 2 claws as shown in the illustration, push the leak detection pump sub-assembly upwards using a screwdriver to remove it.

      Tech Tips

      Tape the screwdriver tip before use.

    4. Check if the charcoal canister sub-assembly contains foreign matter such as mud or water.


      1. B00760T

        Visually check that the inside of the charcoal canister sub-assembly is free of foreign matter.

      2. Hold the charcoal canister sub-assembly upside down to make sure that it is free of foreign matter.

        If the charcoal canister sub-assembly contains foreign matter, replace the canister (charcoal canister assembly).