| DTC Code | DTC Name |
|---|---|
| P043E00 | Evaporative Emission System Leak Detection Reference Orifice Low Flow |
| P043F00 | Evaporative Emission System Leak Detection Reference Orifice High Flow |
| P24007E | Evaporative Emission System Leak Detection Pump Control Circuit Actuator Stuck On |
| P24007F | Evaporative Emission System Leak Detection Pump Control Circuit Actuator Stuck Off |
| P24187E | Evaporative Emission System Switching Valve Control Circuit Actuator Stuck On |
DTC SUMMARY
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory | Note |
|---|---|---|---|---|---|---|
| P043E00 | Evaporative Emission System Leak Detection Reference Orifice Low Flow | Reference orifice clogged during key-off EVAP monitor |
|
Comes on | DTC stored | SAE Code: P043E |
| P043F00 | Evaporative Emission System Leak Detection Reference Orifice High Flow | Reference orifice high-flow during key-off EVAP monitor |
|
Comes on | DTC stored | SAE Code: P043F |
| P24007E | Evaporative Emission System Leak Detection Pump Control Circuit Actuator Stuck On | Leak detection pump on malfunction during key-off EVAP monitor |
|
Comes on | DTC stored | SAE Code: P2402 |
| P24007F | Evaporative Emission System Leak Detection Pump Control Circuit Actuator Stuck Off | Leak detection pump off malfunction during key-off EVAP monitor |
|
Comes on | DTC stored | SAE Code: P2401 |
| P24187E | Evaporative Emission System Switching Valve Control Circuit Actuator Stuck On | Vent valve on (closed) malfunction during key-off EVAP monitor |
|
Comes on | DTC stored | SAE Code: P2419 |
| DTC No. | Monitoring Item | Detection Timing | Detection Logic | SAE |
|---|---|---|---|---|
| P043E00 | Reference orifice clogged | While engine switch off | 2 trip | P043E |
| P043F00 | Reference orifice high-flow | While engine switch off | 2 trip | P043F |
| P24007E | Leak detection pump stuck on | While engine switch off | 2 trip | P2402 |
| P24007F | Leak detection pump stuck off | While engine switch off | 2 trip | P2401 |
| P24817E | Vent valve stuck closed | While engine switch off | 2 trip | P2419 |
Tech Tips
The reference orifice is located inside the canister pump module.
MONITOR DESCRIPTION
5 hours* after the engine switch is turned off, the leak detection pump creates negative pressure (vacuum) in the EVAP system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.
Tech Tips
*: If the engine coolant temperature is not less than 35°C (95°F) 5 hours after the engine switch is turned off, the monitor check starts 2 hours later. If it is still not less than 35°C (95°F) 7 hours after the engine switch is turned off, the monitor check starts 2.5 hours later.
| Sequence | Operation | Description | Duration |
|---|---|---|---|
| - | ECM activation | Activated by soak timer, 5, 7 or 9.5 hours after engine switch turned off. | - |
| A | Atmospheric pressure measurement | Vent valve is turned off (vent) and EVAP system pressure is measured by ECM in order to register atmospheric pressure. If pressure in EVAP system is not between 70 kPa(abs) and 110 kPa(abs) [10.2 psi(abs) and 16 psi(abs)], ECM cancels EVAP system monitor. |
60 seconds |
| B | First reference pressure measurement | In order to determine reference pressure, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally. | 360 seconds |
| C | EVAP system pressure measurement | Vent valve is turned on (closed) to shut EVAP system. Negative pressure (vacuum) is created in EVAP system, and EVAP system pressure is then measured. Write down measured value as it will be used in leak check If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor. |
15 minutes* |
| D | Purge VSV monitor | Purge VSV is opened and then EVAP system pressure is measured by ECM. Large increase indicates normal. |
10 seconds |
| E | Second reference pressure measurement | After second reference pressure measurement, leak check is performed by comparing first and second reference pressure measurements. If stabilized system pressure is higher than second reference pressure, ECM determines that EVAP system is leaking. |
60 seconds |
| - | Final check | Atmospheric pressure is measured and then monitoring result is recorded by ECM. | - |
*: If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.
| *1 | Purge VSV: Off (Closed) | *2 | Purge VSV: On (Open) |
| *3 | Vent Valve: Off (Vent) | *4 | Vent Valve: On (Closed) |
| *5 | Leak Detection Pump: Off | *6 | Leak Detection Pump: On |
| *7 | Reference Orifice (0.02 inch) | *8 | Canister Pressure Sensor |
| *9 | Canister | *10 | Fuel Tank |
| *11 | Canister Pump Module | *12 | Canister Filter |
| *a | Operation A: Atmospheric Pressure Measurement |
*b | Operation B, E: Reference Pressure Measurement |
| *c | Operation C: EVAP System Pressure Measurement |
*d | Operation D: Purge VSV Monitor |
| *e | Atmospheric Pressure | *f | Negative Pressure |
The leak detection pump creates negative pressure through the reference orifice (in operation B and E). When the system is normal, the EVAP pressure is between 97 to 100 kPa(abs) [14.07 to 14.5 psi(abs)]* and saturated within a minute. If not, the ECM interprets this as a malfunction. The ECM illuminates the MIL and stores a DTC if this malfunction is detected in consecutive drive cycles.
*: Typical value.
MONITOR STRATEGY
| Required Sensors/Components | Canister pump module |
| Frequency of Operation | Once per driving cycle |
CONFIRMATION DRIVING PATTERN
Note
The Evaporative System Check (Automatic Mode) consists of 6 steps performed automatically by the GTS. It takes a maximum of approximately 24 minutes.
Do not perform the Evaporative System Check when the fuel tank is more than 90% full because the cut-off valve may be closed, making the fuel tank leak check unavailable.
Do not run the engine during this operation.
When the temperature of the fuel is 35°C (95°F) or higher, a large amount of vapor forms and any check results become inaccurate. When performing the Evaporative System Check, keep the fuel temperature less than 35°C (95°F).
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the engine switch off and wait for at least 30 seconds.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Engine / Utility / Evaporative System Check / Automatic Mode.
After the "Evaporative System Check" is completed, check for All Readiness by entering the following menus: Powertrain / Engine / Utility / All Readiness.
Input the DTC: P043E00, P043F00, P24007E, P24007F or P24187E
Check the DTC judgment result.
| GTS Display | Description |
|---|---|
| NORMAL |
|
| ABNORMAL |
|
| INCOMPLETE |
|
Tech Tips
If the judgment result is NORMAL, the system is normal.
If the judgment result is ABNORMAL, the system is malfunctioning.