MANIFOLD ABSOLUTE PRESSURE SENSOR INSPECTION

PROCEDURE


  1. INSPECT NO. 1 TURBO PRESSURE SENSOR


    1. A01R4YDC02
      *a

      Component without harness connected

      (No. 1 Turbo Pressure Sensor)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      4 (THIM) - 2 (E2) -20°C (-4°F) 13.8 to 18.6 kΩ
      20°C (68°F) 2.09 to 2.81 kΩ
      80°C (176°F) 0.274 to 0.370 kΩ

      If the result is not as specified, replace the No. 1 turbo pressure sensor.