AIR CONDITIONING SYSTEM, Diagnostic DTC:B1468/68

DTC Code DTC Name
B1468/68 Rear Passenger Side Room Temperature Sensor Circuit

DESCRIPTION

The rear room temperature sensor RH*1 or LH*2 (for front passenger side) is installed in the rear quarter trim board RH*1 or LH*2 to detect the rear room temperature and control the heater and air conditioner auto mode. The resistance of the rear room temperature sensor RH*1 or LH*2 changes in accordance with the rear room temperature for RH*1 or LH*2 seat. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The air conditioning amplifier applies a voltage (5 V) to the rear room temperature sensor RH*1 or LH*2 and reads voltage changes as changes in the resistance of the rear room temperature sensor RH*1 or LH*2.

DTC Code DTC Detection Condition Trouble Area
B1468/68 An open or short in the rear room temperature sensor RH*1 or LH*2 circuit.
  • Rear room temperature sensor RH*1

  • Rear room temperature sensor LH*2

  • Harness or connector between rear room temperature sensor RH and air conditioning amplifier assembly*1

  • Harness or connector between rear room temperature sensor LH and air conditioning amplifier assembly*2

  • Air conditioning amplifier assembly


WIRING DIAGRAM

A01EPOUE55
A01EPOUE56

INSPECTION PROCEDURE

PROCEDURE


  1. READ VALUE USING INTELLIGENT TESTER (AIR CONDITIONER)


    1. Use the Data List to check if the rear room temperature sensor RH*1 or LH*2 is functioning properly.

      Air Conditioner
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Room Temperature Sensor (RP)

      Rear room temperature sensor for RH*1 or LH*2 /

      Min.: -6.5°C (20.3°F)

      Max.: 57.25°C (135.05°F)

      Actual rear room temperature for RH*1 or LH*2 displayed

      Open in the circuit: -6.5°C (20.3°F).

      Short in the circuit: 57.25°C (135.05°F).


      • *1: for LHD

      • *2: for RHD

      OK
      The display is as specified in the normal condition.

    NG
    OK
  2. INSPECT REAR ROOM TEMPERATURE SENSOR

    A01ER2LE03

    1. Remove the rear room temperature sensor Click here.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 (+) - 2 (-) 10°C (50°F) 3.00 to 3.73 kΩ
      15°C (59°F) 2.45 to 2.88 kΩ
      20°C (68°F) 1.95 to 2.30 kΩ
      25°C (77°F) 1.60 to 1.80 kΩ
      30°C (86°F) 1.28 to 1.47 kΩ
      35°C (95°F) 1.00 to 1.22 kΩ
      40°C (104°F) 0.80 to 1.00 kΩ
      45°C (113°F) 0.65 to 0.85 kΩ
      50°C (122°F) 0.50 to 0.70 kΩ
      55°C (131°F) 0.44 to 0.60 kΩ
      60°C (140°F) 0.36 to 0.50 kΩ

      Note

      Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.

      Tech Tips

      As the temperature increases, the resistance decreases (See the graph).


    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (REAR ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)

    A01ERQXE03

    1. A01ERQXE04

      for LHD


      1. Disconnect the z37 sensor connector.

      2. Disconnect the E35 amplifier connector.

      3. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        z37-2 (-)- E35-2 (SG-6) Always Below 1 Ω
        z37-1 (+) - E35-19 (TR7)
        E35-2 (SG-6) - Body ground Always 10 kΩ or higher
        E35-19 (TR7) - Body ground
    2. for RHD


      1. Disconnect the z38 sensor connector.

      2. Disconnect the E35 amplifier connector.

      3. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        z38-2 (-) - E35-2 (SG-6) Always Below 1 Ω
        z38-1 (+) - E35-18 (TR)
        E35-2 (SG-6) - Body ground Always 10 kΩ or higher
        E35-18 (TR) - Body ground

    NG
    OK