LUMBAR SWITCH INSPECTION


  1. INSPECT LUMBAR SWITCH LH

    A01EOVAE12

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      3 (B) - 4 (H) Hold Below 1 Ω
      1 (R) - 2 (E2)
      1 (R) - 2 (E2) Off
      4 (H) - 5 (E2)
      1 (R) - 3 (B) Release
      4 (H) - 5 (E2)

      If the result is not as specified, replace the lumbar switch.

  2. INSPECT LUMBAR SWITCH RH

    A01ER9HE02

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      3 (B) - 4 (H) Hold Below 1 Ω
      1 (R) - 2 (E)
      1 (R) - 2 (E) Off
      4 (H) - 5 (E)
      1 (R) - 3 (B) Release
      4 (H) - 5 (E)

      If the result is not as specified, replace the lumbar switch.