COMBINATION METER REMOVAL

Tech Tips


  • Use the same procedures for RHD and LHD vehicles.

  • The procedures listed below are for LHD vehicles.


  1. DISABLE AUTOAWAY/RETURN FUNCTION


    1. Disable the Autoaway/Return function by changing the customize parameter Click here.

      Note

      Record the current customize parameter setting (whether the Autoaway/Return function is enabled or disabled) in order to restore the current setting after finishing the operation.

      Tech Tips

      Performing the above operation causes the Autoaway/Return function to be disabled when the engine switch is turned off.

    2. Turn the engine switch on (IG). Operate the tilt and telescopic switch to fully extend and lower the steering column.

    3. Turn the engine switch off.

  2. REMOVE ENGINE ROOM SIDE COVER LH


    1. Remove the 7 clips and engine room side cover LH.

      A01EN5SE01
  3. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.

  4. REMOVE INSTRUMENT SIDE PANEL LH


    1. A01EN4GE01

      Place protective tape as shown in the illustration.

    2. Using a moulding remover, detach the 6 claws and remove the side panel.

  5. REMOVE NO. 1 SWITCH HOLE BASE


    1. A01EQ09

      Detach the 5 claws.

    2. Remove the hole base and disconnect the connectors.

  6. REMOVE LOWER INSTRUMENT PANEL PAD SUB-ASSEMBLY LH


    1. A01EP96

      Detach the 8 claws.

    2. Remove the instrument panel pad and disconnect the connector.

  7. REMOVE INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY


    1. A01ENJW

      Detach the 6 claws.

    2. A01EOED

      Detach the 4 claws.

    3. Remove the finish panel and disconnect the connectors.

  8. REMOVE NO. 1 INSTRUMENT PANEL REGISTER ASSEMBLY


    1. A01ERR3

      Detach the 4 claws and remove the register.

  9. REMOVE NO. 3 INSTRUMENT PANEL REGISTER ASSEMBLY


    1. A01ER8Q

      Detach the 5 claws and remove the register.

  10. REMOVE COMBINATION METER ASSEMBLY


    1. A01EMYR

      Remove the 2 screws.

    2. A01EP0I

      Detach the 2 clips.

    3. A01EQUC

      Disconnect the connector and remove the combination meter.