INSPECTION PROCEDURE
PROCEDURE
CHECK CONDITION
Check if the system voice recognition level is low when recognizing a particular voice.
| Result | Proceed to |
|---|---|
| System voice recognition level is low with any voice. | A |
| System voice recognition level is low only for a particular voice. | B |
Tech Tips
System voice recognition level varies depending on voice and pronunciation. This is not a malfunction.
| B |
|
END |
| A |
|
CHECK MICROPHONE AND VOICE RECOGNITION (OPERATION CHECK)
| *a | Microphone Input Level Meter |
| *b | Recording Switch |
| *c | Stop Switch |
| *d | Play Switch |
| *e | Recording Indicator |
Enter the "Microphone & Voice Recognition Check" screen. Refer to Check Mic & Voice Recognition in Operation Check Click here.
When voice is input into the microphone, check that the microphone input level meter changes according to the input voice.
Select the recording switch and perform voice recording.
Tech Tips
Select the recording switch with the blower motor of the air conditioning system stopped. If an outlet of the air conditioning system is facing the microphone, noise may be recorded.
Voice can be recorded up to 5 seconds.
Check that the recording indicator remains on while recording and that the recorded voice is played normally without noise or distortion.
| OK |
|---|
| All check results are normal. |
| NG |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| OK |
|
REPLACE HARD DISC
Replace the hard disc Click here.
Check that voice recognition is normal.
| OK |
|---|
| Voice can be recognized normally. |
| NG |
|
REPLACE MULTI-MEDIA MODULE RECEIVER ASSEMBLY Click here |
| OK |
|
END (HARD DISC IS DEFECTIVE)